CLASSIFICATION
Einstufung
PRELIMINARY
No.
DS-Eval4555-2400
REV.
01
SUBJECT
Thema
EvalBoard PAN4555
PAGE
Seite
8 of 16
CUSTOMER’S CODE
EvalPAN4555
PANASONIC’S CODE
DATE
Datum
30.03.2007
European Technology Center
Panasonic Electronic Devices (EUROPE) GmbH
APPROVED
genehmigt
CHECKED
geprüft
DESIGNED
Erstellt
6. SERIAL PORTS
The evalboard is equipped with a serial port connector (COM2). The COM port can be linked to
either UART1 (SCI1) or UART2 (SCI2) on the module. This is done with the S1 switch, which has
to be set as follows:
UART1
active
1 2 3 4 5 6 7 8
SW1
settings
on
off
on
off off off off off
UART2
active
1 2 3 4 5 6 7 8
SW1
settings
off
on
off
on
off off off off
(Table 3)
Remark:
For
PAN4555
only
UART1
is used, SW1-2 and SW1-4 are have to be set to OFF.
7. RESET
Reset of the testboard and the boards at A,B,C or D can be done with the button named
“RESET” next to the USB socket.
8. BDM CONNECTOR
Reprogramming of PAN4555 can be done via the on-board BDM connector.
For programming, the P&E USB HCS08/HCS12 Multilink adapter USB-ML-12 available through
http://www.pemicro.com/
is recommended, but any programmer capable of flashing the
MC9S08GT60 Controller on the Module can be used.
The 6-pin BDM header has the same pinning as the Multilink adapter cable and is located
between the reset switch and the COM2 Connector.
Please make sure that pin1 of the plug connects to pin1 of the header. The correct device
selection for PAN4555 is a Motorola MC9S08GT60.