background image

#

Check that the area around the
lamp unit has cooled down.

$

Use a Phillips screwdriver to turn
the lamp unit cover fixing screws
at the bottom of the projector,
and then remove the lamp unit
cover from the projector.

E

NGLISH

-3

%

Use a Phillips screwdriver to
loosen the two lamp unit fixing
screws until the screws turn
freely. Then hold the handle of
the lamp unit and gently pull it
out from the projector.

&

Insert the new lamp unit while
making sure that the direction
of insertion is correct, and then
use a Phillips screwdriver to
securely tighten the lamp unit
fixing screws.

When inserting the new lamp
unit, be sure to push it in at the
point 

A

and 

B

.

'

Install the lamp unit cover, and
then use a Phillips screwdriver
to securely tighten the lamp
unit cover fixing screws.

(

Insert the power cord plug into
the wall outlet and then press
the MAIN POWER switch.

)

Press the POWER button so
that a picture is projected onto
the screen.

*

Press the MENU button to
display the menu screen, and
then press the 

F

or 

G

button

to select the “OPTION” menu.

Lamp unit replacement procedure

NOTE:

B

Be sure to install the lamp unit
and the lamp unit cover
securely. If they are not
securely installed, it may cause
the protection circuit to operate
so that the power cannot be
turned on.

A

B

Lamp unit cover

Lamp unit cover fixing screws

Handle

Lamp unit fixing screws

p05-12(LAX100)en̲fr    07.4.9  23:29    ページ 3

Summary of Contents for ET-LAX100

Page 1: ... new product Disposing of this product correctly will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accor...

Page 2: ...onnect the power cord plug from the wall outlet Precautions with regard to safety Warning The lamp unit should only be replaced by a qualified technician When replacing the lamp allow it to cool for at least one hour before handling it BThe lamp cover gets very hot and contact with it can cause burns Notes on replacing the lamp unit BThe light generating lamp is made of glass so dropping it or all...

Page 3: ... the new lamp unit be sure to push it in at the point A and B Install the lamp unit cover and then use a Phillips screwdriver to securely tighten the lamp unit cover fixing screws Insert the power cord plug into the wall outlet and then press the MAIN POWER switch Press the POWER button so that a picture is projected onto the screen Press the MENU button to display the menu screen and then press t...

Page 4: ...ER button This will reset the cumulative usage time for the lamp unit to zero Replace the air filter with the new filter which is supplied as an accessory while referring to the replacement procedure which appears in the Operating Instructions for the LCD projector Press the ENTER button and then press the F or G button to select LAMP RUNTIME Press and hold the ENTER button for approximately 3 sec...

Reviews: