Adjustable Range Reflective Photoelectric Sensor
EQ-500
SERIES
BGS
L-ON
D-ON
FGS
L-ON
D-ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Setting distance
Non-detectable area
Detectable range
PRECAUTIONS FOR PROPER USE
Wiring
Part description
Operation mode switch
BGS/FGS function (DC-voltage type only)
•
DC-voltage type sensor incorporates BGS/FGS function.
Select either the BGS or FGS function depending on the
positions of the background and sensing object.
•
BGS/FGS function is set with the operation mode switch.
•
FGS function is used when the sensing object contacts
the background (conveyor, etc).
•
Depends on a selection of either BGS or FGS function,
the output operation changes as follows.
•
Check all wiring before applying power since incorrect
wiring may damage the internal circuit. Also, carefully
tighten the terminal screws so that the wires of adjacent
terminals do not touch.
•
The mounting hole for the terminal cover fixing screws
inclines 70 degrees to the terminal cover, as shown in the
figure below.
To avoid damaging this product or screw, take care when
tightening or loosening a screw.
Notes: 1) The operation mode switch of the DC-voltage type is the DIP switch.
Refer to “DC-voltage type” of
“Operation mode switch”
for details.
2) Incorporated on
EQ-5□T
only.
Note: Turn the operation mode switch gradually and lightly with the attached
screwdriver. Turning with excessive strength will cause damage to the
adjuster.
Multi-voltage type (L-ON/D-ON mode only)
DC-voltage type
Operation mode switch
Description
Detection-ON mode is obtained when the switch
is turned fully clockwise (L side).
Detection-OFF mode is obtained when the switch
is turned fully counterclockwise (D side).
Distance adjuster (2-turn)
Adjuster indicator
Stability indicator (Green)
Operation indicator (Orange)
OFF-delay timer adjuster (Note 2)
ON-delay timer adjuster (Note 2)
Operation mode switch (Note 1)
L
D
BGS
FGS
Timer ON
OFF
N.C.
N.C.
L-ON/D-ON mode
BGS/FGS mode
Timer mode
Not used
•
To maintain water-resistance, the cable should have
an outer diameter between ø9 to ø11 mm
ø0.354 to
ø0.433 in
with a smooth covering material that allows the
attached conduit connector to be securely tightened; the
tightening torque of the screw should be of 1.5 to 2.0 N·
m.
•
If an external surge voltage exceeding 4 kV is impressed
(DC-voltage type: 1 kV), the internal circuit will be
damaged, and a surge suppressing element should be
used.
•
Prepare the cable end as shown below.
Dimensions of the suitable crimp terminals
Round type
Y-shaped type
(After crimping)
7.5
0.295
or less
22
0.866
or less
17
0.669
or less
7
0.276
or less
10
0.394
or less
ø
3.6
ø
0.142
or more
(After crimping)
7.5
0.295
or less
22
0.866
or less
17
0.669
or less
7
0.276
or less
10
0.394
or less
3.6
0.142
or more
(Unit: mm
in
)
Screw for terminal cover fixing
Screwdriver
•
The size of conduit is M20 × 1.5 mm
0.787 in
.
•
If pressure terminals are to be used, affix the connected
pressure terminals to a terminal (M3.5 screw).
Conduit connector construction and cabling
Note: When assembling the conduit connector, pay attention to the direction
of the gland packing.
Furthermore, in order to maintain water-resistance, fit the gland
packing such that the seating surface of the gland packing contacts
the packing holder part of the terminal cover evenly.
Gland packing (Note)
Gland
Power supply
Conduit connector
Output
37 mm
1.457 in
25 mm
0.984 in
•
The tightening torque for the terminal screws should be
0.3 to 0.5 N·m.
Note: Use crimp terminals with insulating sleeves.
Recommended crimp terminal: Nominal size 1.25 × 3.5
0.049 × 0.138
.