background image

EF-S1C

Electrostatic Sensor Controller

7

NAVI MODE

RUN MODE

6

PART DESCRIPTION

2

MODE key

Jog switch

MODE indicator / 

PRO (Yellow)

Digital display (Green, Red)

MODE indicator / DIST (Yellow)

MODE indicator /

HOLD (Yellow)

MODE indicator / RUN (Green)

Output 1 operation indicator (Orange)

Select 1 indicator (Yellow)

Output 2 operation indicator (Orange)

Select 2 indicator (Yellow)

 MODE indicator / CUSTOM (Yellow)

MODE indicator / TIMER (Yellow)

Timing indicator 

(Green)

1

2 3

Thank  you  very  much  for  using  Panasonic  products.  Please  read  this  Instruction 

Manual  carefully  and  thoroughly  for  the  correct  and  optimum  use  of  this  product. 

Kindly keep this manual in a convenient place for quick reference.

٨
٨

Never use this product with a device for personnel protection.

In  case  of  using  devices  for  personnel  protection,  use  products

which meet laws or standards, such as OSHA, ANSI or IEC etc., for

personnel protection applicable in each region or country.

WARNING

How to mount the sensor head

Ԙ

ԙ

Insert the sensor head connector into the inlet until it 

clicks.

Fit the cover to the connector.

MOUNTING

3

Take care that if the front part is lifted without pushing the 

controller  forward,  the  hook  on  the  rear  portion  of  the 

mounting section is likely to break.

Note:

How to remove the controller

Ԙ
ԙ

Push the controller forward.

Lift up the front part of the controller to remove it.

Ԙ

ԙ

Ԙ

ԙ

Fit the rear part of the mounting section of the controller 

on a 35mm width DIN rail.

Press down the rear part of the mounting section of 

the unit on the 35mm width DIN rail and fit the front 

part of the mounting section to the DIN rail.

How to mount the controller

Ԙ

ԙ

Ԙ

Sensor head

connector

Cover

ԙ

35mm width DIN rail

OUTLINE

1

٨

٨

This product can be used in combination with a exclusive sensor head (

EF-S1HS

)

(optional) to monitor electrical potentials on object surfaces.

It can also be used together with an ionizer to check results of charge removal

processes.

٨

In this mode, the current measurement value and threshold value are displayed,

(Note 1)

 and the threshold value can be set and 0-Adjust, key lock and display

value hold and charge removal time measurement operations can be carried out.

I/O CIRCUIT DIAGRAM

4

*1

Non-voltage contact or 

NPN transistor open collector

High (+V, or open): Invalid

Low (0 to +2V):Valid

or

Color code

100mA max.

100mA max.

*

1

Users' circuit

Internal circuit

Load

Load

24V DC

r

10%

(Brown) + V

(Grey) Analog output

(Black) Output 1

(Pink)Timing input / 0-Adjust input

(White) Output 2

(Blue) 0V

5V

100

ǡ

Se

ns

or

 ci

rcu

it

+
-

If using together with an ionizer manufactured by Panasonic, share the 0V line of this product 

with the ground of the ionizer, and carry out 0-Adjust when doing 0V measurements.

Note:

<Points to note when using analog output>

Because  the  0V  lines  for  judgment  output  and 

analog output are common, the analog output may

vary depending on the load current.

In order to satisfy the linearity specifications for the 

analog output, do not use the judgment output.

٨

If the MODE key is pressed, the mode can be changed to a different mode.

٨

If 'PRO' is selected in NAVI mode, the mode changes to PRO mode.

Basicsystem of operation for PROmode

PRO2

Current value save

PRO4

PRO5

Selects a function in CUST mode

to display.

CUSTOM mode display

Allows basic configuration infor-

mation to be set in a single step,

by inputting a 8-digit code.

Coding

All settings, except for data bank,

revert to factory settings.

Reset

PRO3

Loads configuration  setting  from

the data bank.

Data bankload

Saves configuration  setting  from

the data bank.

Data banksave

PRO6

Output mode

Output form

Sets the  viewing orientation of

the digital display.

Displayturning

PRO1

Switches among response times.

Response time change

Calibration

Analog output focus

Sets hysteresis.

Hysteresis

Sets the digital display to turn

ON/OFF.

ECOmode setting

This  simultaneously displays  the

stored measurement value  and

the current measurement value.

Stored value display

Select threshold value  display /

symbol display for left digital dis-

play.

Symbol displaysetting

This  sets  the  focus  for  analog

output.

This calibrates the measurement

values.

This saves the current measure-

ment value.

Displayunit setting

Select whether least significant

digit isdisplayed / not displayed.

(The display will not change even when the jog switch is operated.)

If window comparator mode / 2-output

mode  is selected, threshold value 

setting is carried out.

This  selects  normal  open  or

normal close as the output.

External input setting

Select the external input function.

(Timing input / 0-Adjust)

Basic system of operation for NAVI mode

 (For details, refer to '

NAVI MODE

'.)

This indicates normal sensing 

operation. The threshold value 

can be adjusted and 0-Adjust 

can be carried out as well.

Run

RUN

This sets HOLD mode.

Hold

HOLD

Allows  various  detailed  set-

tings to be configured, such as 

load / save and other settings.

Pro

PRO

Configures operation and period 

of the timer, or charge removal 

time measurement function.

Timer

TIMER

This  displays  items  that  have 

been set using PRO5 mode and 

CUST mode display functions.

Custom

CUST

Distance / Range

DIST

This sets the measurement dis-

tance and measurement range.

Basic system of operation for PRO mode

 (For details, refer to '

PROMODE

'.)

7

9

5

OPERATION PROCEDURE AND BASIC SYSTEM


MODE key

ޓ

Press

ޓ

Press

Turn

'+' side

'-' side

Jog switch

1

3

2

Switching NAVI mode

Canceling while 

setting is in progress

0-Adjust

Confirming menu

settings

Confirming setting 

values

Moving setting menu

Changing setting values

Display value hold



Notes: 1)

2)

Judgment  output  and  analog  output  will  become  unstable  while  setting  operations  are

being carried out. After settings have been completed, use in RUN mode.

If the power is turned off while settings are being confirmed (while the display is blinking), 

the settings may not be applied correctly.

Notes: 1)

At the time of shipment, the threshold value is set to be displayed in the green (left) digital 

display. When the symbol display setting is ON (refer to PRO2 mode), a symbol ("-" only) 

appears in the green (left) digital display.

Press

Press

Threshould

value

Measurement

value

Press for

1 sec. or 

more

Press for

2 sec. or 

more

+

Display value hold

4

Automatically

Automatically

Automatically

Key lock

If  the  MODE  key  and  the  jog  switch  are  pressed 

together for 2 sec. or more, the key lock is canceled.

If the jog switch is turned to the '-' side for 1 sec. or 

more, the hold is canceled.

Press to 

+ side for

1 sec. or more

Notes: 5)

6)

This is enabled when HOLD mode is set to OFF. 

Refer  to  '       

EXTERNAL  INPUT  OPERATIONS 

AND  HOLD  MEASUREMENT

'  in  the  instruction 

manual included (if using the 

EF-S1

 series surface 

potential sensor for the first time) for details on the 

operation when HOLD mode is set to ON.

Only the display value is held. Output is not held.

Press

Press:

Confirmed

+ threshold value setting screen

- threshold value setting screen

Turn

Turn

Threshold value setting

8

Notes: 2)

For  details  on  the  setting  range  for  the  threshold 

value, refer to '

SETTING RANGE

'.

Automatically

0-Adjust setting (cancel)

This sets the measurement value to zero (baseline).

When the MODE key is pressed once more for 1 

sec. or more, 0-Adjust can be canceled.

Notes: 3)

4)

If the measurement value exceeds 

r

200, 0-Adjust 

cannot be carried out.

When 0-Adjust setting input has been selected as 

the external input setting, 0-Adjust can be carried 

out each time using the external input signal.

PRO MODE

9

Turn

Turn

Turn

Turn

4% of measurement range

1% of measurement range

Hysteresis

2% of measurement range

40

10

r

1kVrange

20

80

20

0.5% of measurement range

5

10

0.2% of measurement range

2

4

r

2kVrange

40

Press

Turn

(Calibration)

Press

Press

Current

measurement

value

Expected display

value

Press

Turn

Turn

Press

Press

Responsetime

changefunction

Turn

Response time
10ms
20ms
100ms
200ms
400ms
800ms

Focus

-400 to +400
-200 to +200

-2,000 to +2,000

r

2kV range

-1,000 to +1,000

-200 to +200
-100 to +100

-1,000 to +1,000

r

1kV range

-500 to +500

Analog 1 to +5V

+1 to +5V

(Note)

PRO1 mode setting

Hysteresis

function

Analog

output focus

x5

x10

None

x2

Note:

If a focus has been set for analog output, the resolution will change.

SETTING RANGE

8

٨

٨

٨

The threshold value can be set to within the following range.

Distance 8 to 20.5mm : +5

҇

+Threshold value

҇

+500

(

r

1 kV range)               -5

҈

-Threshold value

҈

-500

Distance 21 to 100mm: +5 

҇

+Threshold value

҇

+1,000

(

r

2 kV range)               -5

҈

-Threshold value

҈

-1,000

0-adjust can be set to within the following range.

-200

҇

Measurement value 

҇

+200

Calibration can be set to within the following range.

0.5

҇

 (Display hold value / Current measurement value)

҇

 10

Distance 8 to 20.5mm : -1,000

҇

Measurement value 

҇

+1,000

Distance 21 to 100mm: -1,999

҇

Measurement value 

҇

+1,999

RUN mode

Refer to '

PROMODE

'.

9

Refer to '

RUN MODE

'.

6

Press

Press

Press

Press

Press

Press

HOLD mode (Note 2)

:

Confirmed

Turn

DIST mode (Note 1)

:

Confirmed

Turn

r

1kV range

 /

Setting distance range 8 to 20.5mm

r

2kV range

 /

Setting distance range 21 to 100mm

TIMER mode (Note 3)

:

Confirmed

Without timer

OFF delay timer / Timer period
ON delay timer / Timer period
ONE-SHOT delay timer / Timer period

Turn

CUSTmode

Turn

Response time change function

Refer to '

PRO MODE

 /

PRO1 mode setting

'.

9

Calibration

Refer to '

PRO MODE

 /

PRO1 mode setting

'.

9

Analog output focus

Refer to '

PRO MODE

 /

PRO1 mode setting

'.

9

Data bank load setting function

Refer to '

PRO MODE

 /

PRO3 mode setting

'.

9

Code setting function

Refer to '

PRO MODE

 /

PRO5 mode setting

'.

9

PROmode

HOLD mode setting

Threshold value / Measurement value

Display value during RUN mode

Threshold value / Peak value
+ peak value / - peak value
Peak value / Measurement value

8

Notes:

For details, refer to '

SETTING RANGE

'.

The values that are displayed during RUN mode will vary as shown in the table below

depending on the setting for HOLD mode. (A '  ' against the displayed value means that

the value isnegative.)

1)

2)

Measurement distance: Set to 0.5mm or

1mm pitch

Measurement range: Set automatically in

accordance with measurement distance

No hold
Peak hold measurement

Ԙ

Peak hold measurement

ԙ

Peak hold measurement

Ԛ

This displays the items that have been set using PRO5

mode and CUST mode display functions, and the set-

tings for these items can be changed.

:

Variable timer period

If HOLD mode is set to ' 

', ' 

' or ' 

', the timer function will be automatically 

set to '         ' (no timer), and it will not be possible to change timer operation.

3)

CME-EFS1C No.0032-47V

Current value is displayed as expected value.

Current valueisdisplayed as1,000 or -1,000.

Only calibration isreset.

(Note 1)

Charge removal time measurement

This  measures  'Charge  removal  time(sec.)'  from 

1000 to 100 automatically and display it.

A start and a stop of the measurement are possible

with the jog switch.

Notes: 7)

This  is  enabled  when 

TIMER  mode  is  set  to 

'Charge  removal  time 

measurement'.

Charge removal time measurement (Note 4)

When charge removal time measurement has been selected, the output operation will be

without timer.

4)

Ex.)

Charge removal time is 1.2 sec.

INSTRUCTION MANUAL

Ramco National

800-280-6933 | [email protected]

www.panasonicsensors.com

Reviews: