Features
Cool/Dry
Mode
Heat Mode
Microprocessor control ensures that the
temperature and humidity levels in the room are
always comfortable.
Microprocessor-Controlled
Operation
ECONAVI features intelligent Human Activity
Sensor and new technologies that can detect
human activity and absence, and optimize air
conditioner operation according to room
conditions.
ECONAVI
Panasonic’s infrared Remote Control with and
easy-to-read LCD Display, gives the user the
capability to adjust & set: temperature, sweep
(louver control), fan speeds, timer and more, for
complete automatic operation.
Wireless Remote Control
Convenient microprocessor control automatically
adjusts fan speed to High, Medium or Low.
According to room temperature to maintain a
comfortable airflow throughout the room.
5 Fan Speeds and Automatic
Fan Operation
The air sweep function moves the louver up and
down in the air outlet, directing air in a “sweeping”
motion around the room and providing comfort in
every corner.
2 air
guides
Air Sweep Control
Louver can be manually set to the desired angle
by remote control.
Louver Control
After setting the temperature and functions
you desire, just relax. If the room temperature
is higher than the set temperature, cooling
operation begins. If the room temperature
is lower than the set temperature, heating
operation begins. During normal thermostat
cycle operation, cooling and heating operations
automatically change in accordance with set
temperature, time and room temperature
(Single Zone Heat Pump unit only).
Automatic Heating and
Cooling Changeover
The remote control unit allows you to set a
wide variety of timer-based operations. Such
functions include automatic ON/OFF with a timer
setting, same time ON/OFF every day, ON timer,
OFF timer and Combination timer.
24-hour Clock with ON/OFF
Program Timer
Automatic Restart Function
after Power Failure
LOW, low fan speed for extra quiet operation.
Quiet Mode
Self-Diagnosing Function
The circulation volume of the refrigerant is
controlled by a pulse type electric control valve.
In order to attain optimum efficiency, when the
power is switched ON, the opening degree of the
electric control valve is controlled between 90
and 480 step.
Electric Refrigerant Control
Valve
By coupling compressor and fan operation,
intermittent operation can be precisely controlled
according to room temperature, so that air is
efficiently dehumidified.
Dry Mode
Right from the start, air is warm and comfortable.
The Hot Start Heating System prevents any cold
blasts at the beginning while the heat pump is
warming up (Heat pump unit only).
Hot Start Heating System
Condensers can take a beating from exposure to
salty air, rain and other corrosive factors.
Panasonic has extended the life of its
condensers with an original anti-rust coating.
Blue Fin Condenser
Room Freeze Protection mode helps prevent
plumbing damage due to sub-Freezing
Temperature. This mode automatically turns on
the compressor for heat pump operation if the
room temperature falls to about 46°F.
*This function may not be performed if the unit is
not powered, or if the unit is unable to operate
such as in protection mode. Please consult with
the HVAC installers.
Room Freeze Protection
Panasonic Adds a "NEW Air Conditioner" Line-up...
Setting Another Milestone in the History of Ductless Split.
No.1* High Energy Efficiency*
Breakthrough technology such as the inverter, enables the highest energy efficiency* in the
industry. Thanks to this exceptional performance, you can enjoy more comfort.
*CS/CU-XE9PKUA as of March 2013
LOW
AMBIENT
OPERATION
SEER
28.5
Powerful Heating at Low Ambient
Inverter Technology
Heating is still possible even if the temperature drops as low as 0˚F for reliable heating in the
middle of the harshest winter.
Panasonic's inverter technology provides optimum power control and extremely efficient
operation by changing the power supply frequency. The result is speedy, flexible operation using
less electricity.
Innovative Inverter Technology
The inverter constantly adjusts the compressor rotation speed to provide optimum
performance at all times. After reaching the set temperature, an inverter air conditioner
continues to operate with minimum power to avoid unnecessary electricity consumption.
Conventional non-inverter air conditioners can only operate at a constant speed, switching the
compressor ON and OFF to maintain the set temperature, which wastes electricity.
20dB
30dB
40dB
50dB
60dB
80dB
Leaves touch together
Whisper voice
In a library
In a office
In a subway
Normal conversation
Inverter Compressor
Panasonic’s Inverter Compressor can achieve high efficiency under
high load conditions.
With accumulated production of 200 Million
compressors, extremely high quality and reliability are proven.
High Efficiency &
High Reliability Material
for longer life span and to
withstand high pressure.
High Efficiency Motor
for wide operating voltage.
Optimum Shape
Muffler
for quiet operation.
Indoor Unit
CS-XE9PKUA / CS-XE12PKUA
12,000
Btu/h
Maximum capacity
8,700
Btu/h
Rated capacity
2,800
Btu/h
Minimum capacity
Even Wider Output Power Range
The graph shows CS-XE9PKUA's wide power
output range during cooling.
* This is maximum elevation difference when the indoor unit is located above the outdoor unit.
*Image of output power fluctuation
Advantages of Inverter Control
Comparing inverter and non-inverter air conditioners to cars.
The accelerator can't be adjusted, so you spend a long
time to get comfortable, then soon become uncomfortable.
Keeps the temperature
comfortable all the time.
Adjusts the accelerator and
thus runs more economically.
Reaches the comfortable
zone quickly.
START
Runs at a fixed speed, so it takes
longer to reach the comfort zone.
The room gets too cold,
then too warm.
Uncomfortable
Comfortable
Uncomfortable
Non-inverter air conditioner
Inverter air conditioner
Cooler
Less Cool
R
oo
m
te
m
pe
ra
tu
re
Setting Temperature
Model No.
Room Freeze Protection
XE9PKUA
XE12PKUA
Unit Model No.
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
CS-XE9PKUA
CU-XE9PKUA
CS-XE12PKUA
CU-XE12PKUA
Performance & Electrical Ratings
Capacity
Cooling
Btu/h
8,700(2,800~12,000)
11,500(2,800~14,000)
Heating
Btu/h
12,000(3,000~18,000) (10,600 at 17˚F)
13,800(3,000~23,000) (13,500 at 17˚F)
Moisture Removal
High
Pints/H
1.3
2.3
Dry Air Flow
High
CFM
405
530
SEER
Cooling
28.5
25.5
EER
Cooling
16.1
14.35
HSPF
Heating
12.5
12.0
Power Supply
V, Phase, Hz
230/208V, 1PH, 60Hz
230/208V, 1PH, 60Hz
Running Amps
Cooling
A
2.5/2.8
3.8/4.2
Heating
A
4.0/4.5
5.2/5.8
Power Input
Cooling
W
540(150-850)
800(150-1,050)
Heating
W
860(150-1,650)
1,150(150-2,100)
Back-up Heater
kW
---
---
Fuse or Circuit BreakerCapacity
A
15
20
Features
Controls
Microprocessor
Microprocessor
Low Ambient Control
Equipped
Equipped
Wireless Remote Controller
Included
Included
Wired Remote Controller (optional)
CZ-RD516C
CZ-RD516C
Fan Speeds
5 Auto
5 Auto
Timer
24hr Program
24hr Program
Air Deflection
Horizontal
Manual
Manual
Vertical
Automatic
Automatic
Air Filter
Wa Anti Microbial Filter
Wa Anti Microbial Filter
Refrigerant
R-410A
R-410A
Refrigerant Control
Electric Expansion Valve
Electric Expansion Valve
Operation Sound
In(Hi / Lo/ Q-Lo)
dB-A
42 / 25 / 20
45 / 28 / 20
Outdoor(Hi)
dB-A
48
49
Refrigerant Piping
Type
Flare
Flare
Discharge
in.
1/4”
1/4”
Suction
in.
3/8”
1/2”
Refrigerant Pipe Length
Ft.
Max. 66
Max. 66
Elevation Difference* Outdoor Above
Ft.
Max. 49
Max. 49
Outdoor Below
Ft.
Max. 49
Max. 49
Dimensions & Weight
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Height
in.
11-5/8”
27-3/8”
11-5/8”
27-3/8”
Width
in.
34-9/32”
34-15/32”
34-9/32”
34-15/32”
Depth
in.
10-1/16”
12-5/8”
10-1/16”
12-5/8”
Net Weight
Lbs.
24
97
24
97
Wireless Remote
Controller
Specifications
Outdoor Unit
CU-XE9PKUA
CU-XE12PKUA
Special Coating Layer
(Fin Cross-section)
Cool air doesn't reach
you directly so your
hands and feet don't
get cold.
Warm feet and no direct
breeze on your face
mean even more
comfort.
Cooling Mode
2 air guides to improve the air flow direction
Heating Mode
Water Air Salt content
Base material
Corrosion-resistant layer
2 air
guides
This feature allows the system to automatically
resume operation at its preset program, after
power is restored from a power failure when
the remote control is in the room.
Unit is equipped with Self-Diagnosing Function
with remote controller. This makes it easier to
diagnose malfunctions, reducing service labors.