9-
14
−
Calibration Channels
The following table shows the calibration channels. It is important to perform the calibration at these
specific channels, as the software performs linear interpolation based upon these channels.
Band Segment
Calibrating
Channel
0 9
1 67
2 124
E-GSM
(0)
3 975
0 512
1 636
2 761
DCS
(1)
3 885
0 512
1 612
2 710
PCS
(2)
3 810
Calibration Limits
The following tables provide the target output power levels for calibration. For each power level, the target
power is listed in the Nominal column. The calibrated power must always fall within the Target Min and
Max ranges listed to the right of the Nominal target.
E-GSM 900
Output (dBm)
Limits
Power Level
(PL)
Target
Min
Max
5
32.25
32.0
32.5
6
30.5
30.0
31.0
7
29.0
28.25
29.5
8
27.0
26.25
27.75
9
25.0
24.25
25.75
10
23.0
22.25
23.75
11
21.0
20.25
21.75
12
19.0
18.25
19.75
13
17.0
16.25
17.75
14
15.0
14.25
15.75
15
13.0
12.25
13.75
16
11.0
10.25
11.75
17
9.0
8.25
9.75
18
7.0
6.25
7.75
19
5.0
4.0
5.75
PROVISIONAL ISSUE
Summary of Contents for EB-X700
Page 91: ... 9 23 10 From the Modes pull down menu select EEPROM PROVISIONAL ISSUE ...
Page 107: ...12 6 Mini SD SIM PCB 12 6 PROVISIONAL ISSUE ...
Page 109: ...12 8 LCD PCB 12 8 PROVISIONAL ISSUE ...
Page 110: ...13 LAYOUT DIAGRAMS 13 1 Main PCB Top View 13 1 1 2K PROVISIONAL ISSUE ...
Page 111: ...13 2 Main PCB Bottom View 13 2 1 5K 10K 10K 10K 10K 10K 1 5K PROVISIONAL ISSUE ...
Page 112: ...13 3 LCD PCB Bottom View 13 3 PROVISIONAL ISSUE ...