Panasonic DV-08VRE2 Installation Instructions Manual Download Page 8

6

Fig. 15

PRACTICAL GUIDE TO INSTALLATION

Properly insulate the area around the fan to 
minimize building heat loss and gain. (Fig.15)
Loose fill or batt insulation can be placed 
directly over the fan housing in the attic. Our 
fans and fan/light combination units do not 
create excessive heat that is a common problem 
with recessed light fixtures or some 
competitor’s fan/light combination. Our 
efficient, cool-running motors and our LED lamp 
do not create enough ambient heat to be 
subjected to these limitations.

HVICertifiedperformancebasedonHVIProcedures915,916and920.

FV-08VRE2

4

6

1.0

120

60

1.0

18.5

11.0

18.5

11.0

1340

1340

80

80

8.6(3.9)

 Fan

 Lamp

COMPATIBLE DIMMERS (NOT SUPPLIED)

SPECIFICATIONS

The ducting from this fan to the outside of the 
building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, 
straightest duct routing possible for best performance, and avoid installing the fan with smaller 
ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold 
growth. Fans installed with existing ducts may not achieve their rated air flow.

mastic or approved foil 

faced tape. 

Model No.

Exhaust

     Air 
direction

Voltage
    (V)

Noise at 
0.1''WG
 (sones)

Speed at 
0.1''WG
 (rpm)

Air volume 
at 0.1''WG
    (CFM)

Weight 
 lb. (

kg

)

      Power 
consumption 
        (W)

    Duct 
diameter 
(inches)

Frequency
     (Hz)

PRODUCT SERVICE

Warning Concerning Removal of Covers.
The unit should be serviced by qualified technicians only.
Your product is designed and manufactured to ensure a minimum of maintenance.
Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) 
or 1-800-669-5165 (Canada). 

P0916  08VRE2421

Two Riverfront Plaza, Newark, NJ 07102 

Corporation

2016

If

 

you want

 

to

 

connect a dimmer, please get the

suitable

dimmer’s

information

from

the

website

which

is

written

on

the

lamp’s

packaging

.

 

Summary of Contents for DV-08VRE2

Page 1: ... maintain the product after the installation and this booklet should be presented to users Please retain this booklet for future reference INSTALLATION INSTRUCTIONS Ventilating Fan 2 3 3 4 5 7 4 4 4 5 7 7 BACK COVER BACK COVER BACK COVER BACK COVER COMPATIBLE DIMMERS NOT SUPPLIED GENERAL SAFETY INFORMATION DESCRIPTION CONTENTS UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM INSTALLATION B...

Page 2: ...ire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities To reduce the risk of injury loss of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions The following symbol word panels are used to classify and describe the level of hazard inj...

Page 3: ...ving lighting device that uses one 11 W BR30 shape LED lamp model 11BR30G4DIM 927 GU24 from the company Green Creative and produces almost the same illumination as a standard 65 W incandescent lamp It also incorporates a thermal cut off for safety The trim ring is a spring loaded quick remove type A damper for preventing air counterflow is provided The blower uses a high capacity sirocco fan devel...

Page 4: ... interference received including interference that may cause undesired operation This product may be used with optional dimmer switch in accordance with dimmer switch instruction instructions Risk of Fire Type IC Inherently Protected Only Use LED Lamp Max 11W Type GU24 DESCRIPTION CONTINUED UNPACKING 4 Trim ring Fan body Adaptor Fan Blower unit Motor LED lamp Junction box Suspension bracket Damper...

Page 5: ...Insert the suspension brackets into the fan body from each side of the bracket cover Fig 1 If spacing A between center joists is 12 inches cut all suspension brackets along the two C cuts with a hacksaw or other tools Before After 2 C cuts UP Ceiling Suspension bracket Joist Joist Fan body Fig 2 Suspension bracket 1 8 3 2 About 3 8 9 5 Long hole Unit inches mm 4 Long screws ST4 2X20 joists Fig 3 4...

Page 6: ...duit Neutral to white Live to black Live to black Earth ground to green Fig 5 Wire nut CAUTION Mount junction box cover carefully so that lead wires are not pinched 9 Mount back the junction box cover 10 Install a circular duct and secure it with clamps or wire ties and seal it with mastic or approved foil tape A 4 or 6 inch circular duct is needed to connect to the relevant part of adaptor Fig 6 ...

Page 7: ...nzene thinner or any other such chemicals for cleaning the ventilating fan 4 Remove dust and dirt from fan body using a vacuum cleaner Fig 12 3 Dry the trim ring after cleaning 6 Replace the trim ring Fig 9 5 Using a cloth dampened with kitchen detergent remove any dirt from fan body Wipe dry with clean cloth Fig 13 Fig 12 Fig 13 Gloves Vacuum cleaner Disconnect power source before working on unit...

Page 8: ...e of the fan Use the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existing ducts may not achieve their rated air flow mastic or approved foil faced tape Model No Exhaust Air direction Voltage V Noise at 0 1 WG sones Speed...