174
Problem Solving
Email ABBR Programming Errors
■
Error Messages Sent to the Sender
Error messages that are emailed from your machine to the original sender during remote programming of the Auto
Dialler via email.
Error Message
Possible Cause / Action
1
554 Data transfer error (broken header)
The header or sub header decoding is being processed while the
message finished, try again.
2
554 Data transfer error (broken data)
Multiple contents are present and being processed while the
message finished, try again.
3
554 Data transfer error (FAX module)
Data transfer error occurred in the FAX module while communicating
with the LAN module, try again.
4
554 MIME attachment not supported
(message/file)
MIME attachment is not supported during this operation, resend
using plain text in the message body only.
5
554 MIME format not supported
MIME file type is not supported, resend using plain text in the
message body only.
6
554 G3 relay permission denied
The requested domain for Relayed XMT is not registered.
7
554 Relay address unknown
The telephone number of end receiving station for the Relayed XMT
is unknown.
8
554 Memory full (FAX module)
FAX Memory is full, try again later.
9
554 Data transfer error
Other errors not listed above, try again later.