7 Service Mode
7.1. Self-Diagnosis and Special Mode Setting
7.1.1. Self-Diagnosis Functions
Self-Diagnosis Function provides information for errors to service personnel by “Self-Diagnosis Display” when any error has
occurred.
U**, H** and F** are stored in memory and held.
You can check latest error code by transmitting [0] [1] of Remote Controller in Service Mode.
Automatic Display on FL will be cancelled when the power is turned off or AC input is turned off during self-diagnosis display is ON.
Error Code
Diagnosis contents
Description
Monitor Display
Automatic FL display
U30
Remote control code error
Display appears when main unit and remote
controller codes are not matched.
No display
“*” is remote controller code of the
main unit.
Display for 5 seconds.
U59
Abnormal inner temperature
detected
Display appears when internal temperature of
deck reaches limit temperature.
The power is turned off forcibly.
For 30 minutes after this, all key entries are
disabled. (Fan motor operates at the highest
speed for the first 5 minutes. For the
remaining 25 minutes, fan motor is also
stopped.) The event is saved in memory as
well.
No display
U59 is displayed for 30 minutes.
U61
The unit is carrying out its
recovery process.
No display
U71
HDMI incompatible error
(HDCP incompatible)
Display this error when the equipment
(compatible with DVI such as TV, amplifier
etc.) connected to the unit by HDMI is
incompatible with HDCP.
*HDCP=High-bandwidth
Digital
Content
Protection
No display
U72
HDMI connection error
(communication error)
This error is displayed when there are any
communication problems with the unit and the
equipments (TV, amplifier etc.) connected to
the unit by HDMI. (or when there is a problem
with the HDMI cable)
U72 display disappears when
error has been solved by Power
OFF/ON of connecting equipment
or by inserting/removing of HDMI
cable.
U73
HDMI connection error
(authentication error)
When authentication error occurs while the
equipments (TV, amplifier etc.) are connected
by HDMI. (or when there is a problem with the
HDMI cable)
No display
U73 display disappears when
error has been solved by Power
OFF/ON of connecting equipment
or by inserting/removing of HDMI
cable.
U88
The unit is carrying out its
recovery process.
No display
U99
Hang-up
Displayed when communication error has
occurred between Main microprocessor and
Timer microprocessor.
No display
Displayed
is
left
until
the
[POWER] key is pressed.
H19
Inoperative fan motor
When inoperative fan motor is detected after
powered on, the power is turned off
automatically.
The event is saved in memory.
No display
No display
15
DMR-EH67GN / DMR-EH67GC / DMR-EH67GCS
Summary of Contents for DMR-EH67GC
Page 5: ...2 2 Precaution of Laser Diode 5 DMR EH67GN DMR EH67GC DMR EH67GCS ...
Page 8: ...4 Specifications 8 DMR EH67GN DMR EH67GC DMR EH67GCS ...
Page 9: ...9 DMR EH67GN DMR EH67GC DMR EH67GCS ...
Page 10: ...5 Location of Controls and Components 10 DMR EH67GN DMR EH67GC DMR EH67GCS ...
Page 11: ...11 DMR EH67GN DMR EH67GC DMR EH67GCS ...
Page 13: ...6 1 2 When the Forcible Disc Eject can not be done 13 DMR EH67GN DMR EH67GC DMR EH67GCS ...
Page 29: ...9 2 P C B Positions 29 DMR EH67GN DMR EH67GC DMR EH67GCS ...
Page 39: ...10 1 3 Checking and Repairing of Main P C B 39 DMR EH67GN DMR EH67GC DMR EH67GCS ...
Page 40: ...10 1 4 Checking and Repairing of HDD 40 DMR EH67GN DMR EH67GC DMR EH67GCS ...
Page 44: ...44 DMR EH67GN DMR EH67GC DMR EH67GCS ...
Page 70: ...DMR EH67GN DMR EH67GC DMR EH67GCS 70 ...
Page 89: ...15 1 2 Packing Accessories Section 89 DMR EH67GN DMR EH67GC DMR EH67GCS ...