Item
FL display
Key operation
Mode name
Description
Front Key
Rating password
The audiovisual level setting password is
initialized to Level 8.
While the unit is on, press and
hold [OK], [B] and [Y] on the remote
control at the same time for more
than 5 seconds.
- "00 RET" is displayed on the unit's
display.
Repeatedly press
[
]
on the
remote control or [POWER] on the
unit until "03 VL" is displayed on the
unit's display.
Press [OK] on the remote control
or [OPEN/CLOSE] on the unit.
Service Mode
Setting every kind of modes for servicing.
*Details are described in
7.1.3. (BD) Service
Mode at a glance
.
Turn the power off.
Press the [5] [9] and [R] button
simultaneously for five seconds,
then [70 RET] is displayed on FL.
Press the
[
]
button to select
until [80 SRV] is displayed on FL.
Press the [OK] button .
*The command is transmitted by
attached remote control.
BD-ROM history cleaning < Persistent Storage> of BD-ROM standard is
cleaned.
Screen display: [The player's history data has
been cleared.] is displayed for five seconds.
When the power is on, disc is not
in tray, press and hold [6], [7] and
[Y] on the remote control at the
same time for more than 5 seconds.
- "50 RET" is displayed on the unit's
disply.
Repeatedly press
[
]
on the
remote control or [POWER] on the
unit until "51 NOP" is displayed on
the unit's display.
Press and hold [STOP] on the
remote control until "52 BRE" is
displayed on the unit's display.
Press [OK] on the remote con-
trol or [OPEN/CLOSE] on the unit.
Forced disc eject
Removing a disc that cannot be ejected.
The tray will open and unit will shift to P-off
mode.
While Demonstration Lock is being set, this
Forced disc eject function is not accepted.
While the unit is off, press and
hold [OK], [B] and [Y] on the remote
control at the same time for more
than 5 seconds.
- "00 RET" is displayed on the unit's
display.
Repeatedly press
[
]
on the
remote control or [POWER] on the
unit until "06 FTO" is displayed on
the unit's display.
Press [OK] on the remote control
or [OPEN/CLOSE] on the unit.
Forced power-off
When the power button is not effective while
power is ON, turn off the power forcibly.
Display in P-off mode.
Press [POWER] key over than 10
seconds.
Summary of Contents for DMP-BDT110GC
Page 2: ...2 ...
Page 6: ...6 1 3 Caution for AC cord Only for BDT110GC ...
Page 8: ...8 2 2 Precaution of Laser Diode ...
Page 10: ...10 3 Service Navigation 3 1 Service Information ...
Page 15: ...15 5 Location of Controls and Components ...
Page 16: ...16 ...
Page 42: ...42 4 Apply the lubricants to the 7 points as shown in Figure ...
Page 43: ...43 9 3 3 How to Clean the Lens of Optical Pick UP ...
Page 44: ...44 9 4 Adjustment of BD Drive 9 4 1 Repair Flowchart ...
Page 45: ...45 9 4 2 Distinction Analysis 9 4 2 1 Distinction Analysis Flowchart ...
Page 49: ...49 10 1 2 Checking and Repairing of Digital P C B ...
Page 71: ...71 16 Schematic Diagram for printing with A4 size ...