![Panasonic DMP-BD85EB Service Manual Download Page 42](http://html.mh-extra.com/html/panasonic/dmp-bd85eb/dmp-bd85eb_service-manual_258484042.webp)
42
1. Connect the Serial cable (RFKZ0139) between serial port
connector (P51601) on the Digital P.C.B. and PC's serial
port.
• Confirm the PC’s serial port number (COM1, COM2,
etc.) connected to serial cable (RFKZ0139), the port
number may be set after this procedure.
2. Start the Adjustment software, then click the [Start(S)].
[Selection of Model Name]
3. Select the model number and click the [OK] button.
• If several other model names might appear, please
select the sure model number for the adjustment.
[Setting of Adjustment]
4. Click the [Utility] button.
5. Click the [COM Setup] button.
6. Select the COM number that connect the serial cable
(RFKZ0139) and click the [OK] button.
7. Click the [Exit] button.
8. Click the [Adjustment] button.