36
15. Input the number of fifteen digits of QR code label (label
of the lower) pasted to OPU assay of the traverse unit,
and select "OK".
16. Take out the SD DIAG Card.
17. Detach the AC power supply code from the power supply
outlet, and select “OK”.
18. Turn off the switch of serial cable (RFKZ0139).
19. Connect the AC power supply code with the power supply
outlet, and select “OK”.
20. Adjust “DIAG” “SPEC” “LPC” by the automatic operation.
(It takes a few minutes.)
21. Set the DVD-RAM test disc (X5RAM-BPS), and select
“OK”.
22. Adjust “DISC” by the automatic operation.
23. Take out the DVD-RAM test disc (X5RAM-BPS).
24. Set the BD-ROM test disc (VFF0396), and select “OK”.
Summary of Contents for DMP-B100EB
Page 10: ...10 4 1 Others Licenses ...
Page 11: ...11 5 Location of Controls and Components B100P ...
Page 12: ...12 B100PC ...
Page 13: ...13 ...
Page 23: ...23 9 Disassembly and Assembly Instructions 9 1 Disassembly Flow Chart ...
Page 31: ...31 10 1 2 Checking and Repairing of Main P C B 2 ...
Page 51: ...51 15 1 2 Packing Accessories Section PC8 PC4 PC2 PC7 A2 A5 A8 A5 A1 A1 1 A4 A15 A10 PC1 PC3 ...