25
9.4.
Traverse Unit
NOTE:
The countermeasure against static electricity is necessary
when servicing the surrounding of traverse unit.
Moreover, the traverse unit is the precision optical part.
Take care not to touch surrounding of the lens and not to
shock to the traverse unit.
1. Pull out the P55010(FFC) and the P55011(FFC).
2. Release the connector and latches, pull out the
P55001(FFC), and then remove the traverse unit.
9.5.
Main P.C.B.
1. Remove the connector and the flexible cable.
2. Pull out the P57002(FFC) and the P4001(FFC).
3. Remove the 3 screws and remove the main P.C.B. with
BAT-CONNECTOR P.C.B..
9.6.
Operation P.C.B.
1. Remove the screw and remove the HP P.C.B..
2. Remove the 5 screws and remove the Operation P.C.B..