7.2.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG-PAVC” web-site in “TSN
system”, together with Maintenance software.
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
No.
Parts No.
Connection
Form
1
VFK1976
FP9007 (MAIN) - TOP OPERATION UNIT
19PIN 0.5 FFC
2
VFK1783
P9004 (MAIN) - HOT SHOE UNIT
2PIN CABLE
3
VFK1980
P9002 (MAIN) - EVF UNIT
2PIN CABLE
4
VFK1461
FP9005 (MAIN) - EVF UNIT
20PIN 0.5 FFC
5
VFK1492
FP9004 (MAIN) - LCD HINGE UNIT
26PIN 0.5 FFC
6
VFK1576DC202
P9003 (MAIN) - FLASH SW UNIT
2PIN CABLE
7
VFK1480
FP9001 (MAIN) - MIC FPC UNIT
6PIN 0.5 FFC
8
VFK1441
FP9003 (MAIN) - SIDE OPERATION UNIT
8PIN 0.5 FFC
9
VFK1951
FP9008 (MAIN) - LENS FPC UNIT
39PIN 0.3 FFC
10
VFK1174
FP9002 (MAIN) - CCD UNIT
30PIN 0.5 FFC
11
VFK1576DC202
P9001 (MAIN) - AF ASSIST PCB
2PIN CABLE
12
VFK1576DSC03
P9006 (MAIN) - BATTERY CATCHER UNIT
3PIN CABLE
13
VFK1582A1225
FP9006 (MAIN) - FP8101 (FLASH)
12PIN 0.5 FFC
14
VFK1576DSC03
P9001 (FLASH) - FLASH UNIT
2PIN CABLE
15
VFK1576DC202
P9002 (FLASH) - FLASH UNIT
2PIN CABLE
Summary of Contents for DMCFZ30PP - DIGITAL STILL CAMERA
Page 8: ...8 NOTE Above caution is applicable for a battery pack which is for DMC FZ30 series as well ...
Page 12: ...12 4 Specifications ...
Page 13: ...13 5 Location of Controls and Components ...
Page 14: ...14 ...
Page 15: ...15 ...
Page 23: ...23 8 Disassembly and Assembly Instructions 8 1 Disassembly Flow Chart 8 2 PCB Location ...
Page 26: ...26 Fig D4 8 3 3 Removal of the LCD Case Unit Fig D5 ...
Page 30: ...30 8 3 13 Removal of the Flash PCB Fig D15 8 3 14 Removal of the LCD Unit Fig D16 ...
Page 32: ...32 8 3 17 Removal of the Mic FPC PCB Fig D20 8 3 18 Removal of the Hot Shoe Unit Fig D21 ...