7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
7.3.1.
Extension Cable Connections
CAUTION-1. (When servicing FLASH PCB)
1. Be sure to discharge the capacitor on FLASH PCB.
Refer to “HOW TO DISCHARGE THE CAPACITOR ON FLASH PCB”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH PCB.
3. DO NOT allow other parts to touch the high voltage circuit on FLASH PCB.
No.
Parts No.
Connection
Form
1
RFKZ0416
FP9003 (MAIN) - CCD UNIT
41PIN 0.3 FFC
2
RFKZ0477
FP9005 (MAIN) - LENS UNIT
45PIN 0.4 FFC
3
RFKZ0445
PP9901 (MAIN) - PS9801(SUB)
100PIN B to B
4
RFKZ0416
FP9801 (SUB) - FP9901 (TOP OPERATION P.C.B.)
41PIN 0.3 FFC
5
VFK1906
P8001 (FLASH PCB) - PP9903 (TOP OPERATION P.C.B.)
20PIN B to B
Summary of Contents for DMC-TZ7EB