18
3. Error Code List
The error code consists of 8 bits data and it shows the following information.
Attribute
Main item
Sub item
Error code
Contents (Upper)
Error Indication
High 4bits Low 4 bits
Check point (Lower)
Detecting
device
Part/Circuit
LENS
Lens drive OIS
18*0
1000
PSD (X) error. Hall element (X axis) position detect
error in OIS unit.
OIS X
LENSu NG
OIS Unit
2000
PSD (Y) error. Hall element (Y axis) position detect
error in OIS unit.
OIS Y
OIS Unit
3000
GYRO (X) error. Gyro (IC7101) detect error on Main
P.C.B..
JYRO X
JYRO NG
IC7101 (Gyro element) or IC6001 (VENUS HD)
4000
GYRO (Y) error. Gyro (IC7101) detect error on Main
P.C.B..
JYRO Y
IC7101 (Gyro element) or IC6001 (VENUS HD)
5000
MREF error (Reference voltage error).
OIS REF
LENSSd/DSP
NG
IC9101 (LENS drive) or IC6001 (VENUS HD)
6000
Drive voltage (X) error.
OISX REF
LENSu/LENS
FPC
LENS Unit, LENS flex breaks, IC6001(VENUS HD)
AD value error, etc.
7000
Drive voltage (Y) error.
OISY REF
LENS Unit, LENS flex breaks, IC6001(VENUS HD)
AD value error, etc.
Zoom
(C.B.)
0?10
Collapsible barrel Low detect error
ZOOM L
ZOOMm/
LENSu
(Collapsible barrel encoder always detects Low.)
Mechanical lock, FP9005-(26) signal line or IC6001
(VENUS HD)
0?20
Collapsible barrel High detect error
ZOOM H
(Collapsible barrel encoder always detects High.)
Mechanical lock, FP9005-(26) signal line or IC6001
(VENUS HD)
0?30
Zoom motor sensor error.
ZOOM ENC
Mechanical lock, FP9005-(37), (40) signal line or
IC6001 (VENUS HD)
0?40
Zoom motor sensor error. (During monitor mode.)
Mechanical lock, FP9005-(37), (40) signal line or
IC6001 (VENUS HD)
0?50
Zoom motor sensor error. (During monitor mode with
slow speed.)
Mechanical lock, FP9005-(37), (40) signal line or
IC6001 (VENUS HD)
Focus
0?01
HP High detect error
(Focus encoder always detects High, and not
becomes Low)
FOCUS L
LENS FPC/
DSP
Mechanical lock, FP9005-(26) signal line or IC6001
(VENUS HD)
0?02
HP Low detect error
(Focus encoder always detects Low, and not
becomes High)
FOCUS H
Mechanical lock, FP9005-(26) signal line or IC6001
(VENUS HD)
Lens
18*1
0000
Power ON time out error.
LENS DRV
LENSu
Lens drive system
18*2
0000
Power OFF time out error.
Lens drive system
Adj.History OIS
19*0
2000
OIS adj. Yaw direction amplitude error (small)
OIS ADJ
OIS ADJ
3000
OIS adj. Pitch direction amplitude error (small)
4000
OIS adj. Yaw direction amplitude error (large)
5000
OIS adj. Pitch direction amplitude error (large)
6000
OIS adj. MREF error
7000
OIS adj. time out error
8000
OIS adj. Yaw direction off set error
9000
OIS adj. Pitch direction off set error
A000
OIS adj. Yaw direction gain error
B000
OIS adj. Pitch direction gain error
Summary of Contents for DMC-TZ7EB
Page 13: ...13 4 Specifications ...
Page 15: ...15 5 Location of Controls and Components ...
Page 16: ...16 ...
Page 25: ...25 8 Disassembly and Assembly Instructions 8 1 Disassembly Flow Chart 8 2 PCB Location ...
Page 27: ...27 8 3 2 Removal of the LCD Unit Fig D3 Fig D4 ...
Page 29: ...29 8 3 6 Removal of the Top Operation P C B Fig D8 8 3 7 Removal of the Lens Unit Fig D9 ...
Page 30: ...30 8 3 8 Removal of the Sub P C B Fig D10 8 3 9 Removal of the Flash Unit Flash P C B Fig D11 ...
Page 40: ...40 8 7 Removal of the Zoom Motor Unit 8 8 Removal of the Focus Motor Unit ...
Page 57: ...S 14 ...