23
8.2.
When Replacing the Main P.C.B.
After replacing the Main P.C.B., be sure to achieve adjustment.
The service software is available at “TSN Website”.
8.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
CAUTION. (When servicing Flash Top P.C.B.)
1. Be sure to discharge the E.Capacitor on Flash Top P.C.B..
Refer to “How to Discharge the E.Capacitor on Flash Top P.C.B..
The E.Capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on Flash Top P.C.B..
3. DO NOT allow other parts to touch the high voltage circuit on Flash Top P.C.B..
No.
Parts No.
Connection
Form
1
RFKZ0548
PS9001(MAIN)
←→
PP9501(SUB OPERATION)
20PIN B to B
2
VFK1541
PP9001(MAIN)
←→
PS8001(FLASH TOP)
40PIN B to B