8.2 When Replacing the Main P.C.B.
After replacing the Main P.C.B., be sure to achieve adjustment.
The Maintenance software (DIAS) is available at "software download" on the "Support Information from NWBG/VDBG-AVC" web-site in "TSN system".
8.3 Service Position
This Service Position is used for checking and replacing parts. Use the original cables for servicing.
8.3.1 Extension Cable Connections
CAUTION-1. (When servicing Flash P.C.B.)
1. Be sure to discharge the capacitor on Flash P.C.B.
Refer to "HOW TO DISCHARGE THE CAPACITOR ON FLASH P.C.B.".
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on Flash P.C.B.
3. DO NOT allow other parts to touch the high voltage circuit on Flash P.C.B.
Page 3 of 3
10/28/2017
file://\\royalfs\Service\Technical\Ms.dehghani\All SVC sent by CD\20\DMC-FT25EBAL...