7
Installation of electric bidet seat
In
stall
ation
Remove the installed old seat.
Install the body mounting plate.
Install the body.
1. Loosen the bolt and remove the nut. (Fig. 1)
1. Align the protrusion in the center on the back side of
the body with the one in the center of the body
mounting plate.
2. Lift up the rear part of the body slightly and slide it
towards the body mounting plate until a “click” is
heard.
●
Do not secure the power cord between the body and toilet.
With a tape measure, measure the length of A. (Fig. 3)
Align the center line of the top-mounted bolt with the
reference scale line matching A on the body mounting
plate for preliminary positioning. (Fig. 4)
2. Fit the metal mounting plate to the top-mounted bolt
and screw in the nut. (Fig. 2)
(This nut is applicable to toilet with the bore diameter
of 12 - 17 mm . For other bore diameters, consult our
after-sales service for installation.)
3. For preliminary positioning, secure the top-mounted
bolt to the body mounting plate. (Same on both sides)
Perform the removal operation by
following the Instructions provided
by the purchased toilet.
Remove the body mounting plate.
Press the body assembly / disassembly
button all the way in and remove the
body mounting plate.
(Pull out along the direction of
arrows alternatively.)
49
0
44
0
49
0
44
0
1
3
4
When the rear part of the lid contacts the water tank
of the toilet, or the lifted seat falls down easily.
Move the body mounting plate forwards slightly and
secure it. Install the body again.
A
490
440
490
440
490
440
490
440
B 80 mm
2
4. Adjust the position of the body mounting plate and
ensure B 80 mm. Then, install the body mounting plate
to the toilet.(Fig. 5)
490
440
Example
Bolt
Bolt
Protrusion
Front seat mount
Nozzle compartment
Protrusion
Center line
Tighten
(Example of
A=490 mm)
Nut
Remove
Toilet mounting
hole
Top-mounted
bolt
Metal mounting
plate
Loosen
Fig. 1
Fig. 2
Fig. 4
Fig. 5
Fig. 3
Unscrew
Body assembly /
disassembly button
Seat
Do not press the nozzle
compartment.
(Otherwise, the nozzle may get
stuck.)
The spacing for installing the bolts of the body mounting
plate can be adjusted between 130 - 215 mm.
Do not place the nozzle
compartment at the body base
on the surface of the toilet.
Make sure the front seat mount
is placed on the surface of the
toilet.
Make sure to install the body mounting plate with
B 80 mm. Otherwise, the body may be tilted or a
water leak may occur.
Once the body is installed, lift it up gently to check if it is
installed securely.
As this product is design with a detachable structure to
enable the body to be removed from the toilet, it may
sometimes feel slightly shaky. This is not a malfunction.
For proper installation, be sure
to use the body mounting plate
supplied with the product.