33
HDD READ VERIFY
Inspection
Measure of access time in READ VERIFY
MODE of HDD.
At start
The [*] sign is added every 20 sec-
onds while inspecting.
Two digits on the right side are the
progress level of the inspection (The
unit is %).
Example on the way of inspection:
When HDD is OK after inspection:
(NG is displayed when error is
excluding o )
(Transfer rate is calculated from the
AV scanning result, and when it is
less than 35Mbps, NG is displayed.)
$: [X] is displayed when seek time is
over 270msec., there is error or trans-
fer rate is NG.
Position at $ is space when excluding
those.
##: Number of data of over 100msec.
and less than 270msec.
When it is over 100, [99] is displayed.
When the number is less than 5, we
judge it normal.
Press [3] [2] in service mode.
* When canceling the inspection
mode while executing, do “forced
power-off”.
Method:
Press [POWER] key more than 10
seconds.
HDD Spin-up time
The accumulation value of the Spin-up time
of HDD is displayed.
Spin-up time of HDD is displayed.
(The unit of display is hour.)
Press [3] [3] in service mode.
Item
LCD display
Key operation
Mode name
Description
(Remote controller key)
Summary of Contents for DIGA DMR-XS350EB
Page 5: ...5 2 2 Precaution of Laser Diode ...
Page 9: ...9 3 2 Service Information 3 3 Caution for DivX ...
Page 15: ...15 4 Specifications ...
Page 16: ...16 ...
Page 17: ...17 5 Location of Controls and Components ...
Page 18: ...18 ...
Page 56: ...56 Installation for Rail Throw in the groove of Rail and Tray and slide to the fore of Tray ...
Page 57: ...57 9 2 11 Grease ...
Page 58: ...58 9 2 12 How to Clean the Lens of Optical Pick UP Follow the 9 2 1 Upper Base Ass y ...
Page 61: ...61 10 1 2 Checking and Repairing of DVD Drive ...
Page 62: ...62 10 1 3 Checking and Repairing of AV IO P C B ...
Page 63: ...63 10 1 4 Checking and Repairing of HDD ...
Page 64: ...64 10 1 5 Checking and Repairing of Digital P C B ...
Page 83: ...S 17 ...