Note:

•  The water temperature lowers as the volume of water is increased by opening the Faucet and water temperature rises 

as the volume of water is decreased by closing the Faucet.

•  In case of continuous usage at high temperature setting, water temperature will increase and may cause the control 

device to activate temporarily resulting in water temperature to drop.

•  If you use water at more than one point, the water pressure will drop and the water fl ow may become weak or the 

water temperature may rise. However, this is not a sign of any trouble. Adjust the Hot Water Faucet to a proper level.

•  Do not switch on if there is possibility the water in the heater is frozen.

HOW TO  USE

  Turn on the Main Water Valve.
  Switch on the Miniature Circuit Breaker (MCB) and the ON/OFF DP (Double Pole) Switch. 
  Push the ELB Reset Lever up if it is down.

Min

Max

ELB

ELB Test

ELB Reset

Push Up

Min

Max

ELB

ELB Test

ELB Reset

Push Up

Min

Max

ELB

ELB Test

ELB Reset

Push Up

FILTER
CLEANING

FILTER
CLEANING

FILTER
CLEANING

FILTER

CLEANING

FILTER

CLEANING

FILTER

CLEANING

FILTER

CLEANING

Push

ELB: On condition

ELB: Off condition

  Set the Temperature Control Knob to the desired position.

(a)  When the Temperature Control Knob is set to "Min", temperature level 

is low. 

 (b) 

 

When the Temperature Control Knob is set to "Max", temperature level 
is high.

  Turn on the Hot Water Faucet. The ELB Lamp will light up once the 

appliance operates.

Min

Max

ELB

 

CAUTION

Avoid using dirty water as it may affect heater 
performance and other components.

Always turn on the Cold Water Faucet fi rst and then 
adjust the Hot Water Faucet to get the desired water 
temperature. So as to avoid the danger of scalding when 
operating this appliance.

MAINTENANCE

 

 

WARNING

Switch off the Miniature Circuit Breaker (MCB) before any 
service to avoid electric shock hazards.

1. Inspection on the built-in ELB.

Inspect the built-in ELB (once a month) to avoid a hazard to users such as damage to property, serious injury or 
death.

• Make sure the appliance is in on condition.
• Press the ELB Test Button. If the ELB is in normal condition, ELB Reset Lever will slide down.
• Push up the ELB Reset Lever to reset the ELB.

HOW TO USE ELECTRIC WATER HEATER

DH-6SM1_PH.indb   5

DH-6SM1_PH.indb   5

1/27/2021   12:55:02 PM

1/27/2021   12:55:02 PM

Summary of Contents for DH-6SM1PW

Page 1: ...ERATION EN11 Operating and Installation Instructions Electric Water Heater Household Use Thank you for purchasing this Panasonic product Please read these instructions carefully in order to use this product correctly and safely Before using this product please give your special attention to the SAFETY PRECAUTIONS Please keep this Operating and Installation Instructions for future use Min Max ELB D...

Page 2: ... Service Centre for repairing ƪ This appliance is not to be used for a potable water supply ƪ The appliance must be earthed Improper grounding could cause electric shock ƪ Stop using the appliance when any abnormality failure occurs and switch off the Miniature Circuit Breaker MCB Risk of smoke fire electric shock scalding Example of abnormality or failure The ELB Reset Lever cannot be reset Pleas...

Page 3: ... avoid a hazard due to inadvertent resetting of the thermal cut out this appliance must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility ƪ Do not switch on if there is possibility the water in the appliance is frozen ƪ Never fix the appliance forcibly with tape or adhesives Strictly follow all the in...

Page 4: ...ucet Hot Water Faucet Faucet Temperature Control Knob ELB Lamp Front Plate Filter Knob O Ring Filter Unit Water Outlet Note It is recommended to make the cold water and hot water mixing piping as illustrated ACCESSORIES Description Items Ø6 25 mm M4 1 25 mm Installation Packing Wall Plug 4 pcs Screw 4 pcs Note When removing the appliance from package some water may be found inside This is normal a...

Page 5: ...ILTER CLEANING FILTER CLEANING FILTER CLEANING Push ELB On condition ELB Off condition Set the Temperature Control Knob to the desired position a When the Temperature Control Knob is set to Min temperature level is low b When the Temperature Control Knob is set to Max temperature level is high Turn on the Hot Water Faucet The ELB Lamp will light up once the appliance operates Min Max ELB CAUTION A...

Page 6: ...y to the appliance Check whether the water and electrical connections comply with the Specifications as indicated Make sure to switch on the ON OFF DP Double Pole Switch Make sure to switch on the Miniature Circuit Breaker MCB Make sure the ELB Reset Lever is not slide down Push up the ELB Reset Lever to reset the ELB refer to TEST OPERATION at page EN11 No water flows out from the appliance at al...

Page 7: ...be permanently connected to the electric supply through the ON OFF DP double pole Switch having a contact separation of at least 3 mm in all poles incorporated in the fixed wiring This switch must be clearly identifiable but out of reach of a person using a fixed bath or shower ƪ Use the attached accessories parts for installation CAUTION ƪ This appliance must be installed indoor only ƪ Flexible C...

Page 8: ...N Ensure this appliance is not installed at the place where water existence will lead to smoke emission ignition fire electric shock and damage to property 2 How to remove the Front Plate Make sure the Temperature Control Knob at Min position Remove the Screw at the bottom of the appliance Lift up the Temperature Control Knob to make it free Make sure the Temperature Control Knob is not detached f...

Page 9: ... fixed tightly on the wall by shaking it left and right Note The Back Plate must be mounted with 4 Screws Wall Back Plate Wall Plug Back Plate Wall Plug Wall 4 Electric wiring Make sure rated electrical supply is supplied to this appliance WARNING ƪ Proper size of Flexible Cord and electric wiring must be installed to avoid smoke emission and fire hazards ƪ The appliance must be permanently connec...

Page 10: ... Board Power Supply Terminals Tester Earth Earth Rod WARNING The appliance must be earthed Improper grounding could cause electric shock Earth Rod handling procedure Select adapter place to bury the optional Earth Rod DQ 6H for at least 70 cm below ground surface Ensure that the ground resistance is less than 100 If it is not drive the Rod deeper into ground surface or use 2 or 3 Rods Ground Surfa...

Page 11: ...t Plate OFF position FILTER CLEANING D Cut Position Back Plate Front Plate Back Plate Screw Front Plate Press TEST OPERATION WARNING ƪ Inspect the built in ELB once a month to avoid a hazard to users such as damage to property serious injury or death ƪ If the ELB Reset Lever cannot be reset even if you push it up or if it soon slides down during operation do not use the appliance and contact an au...

Page 12: ...a Berhad 2020 Panasonic Manufacturing Malaysia Berhad 196501000304 No 3 Jalan Sesiku 15 2 Section 15 Shah Alam Industrial Site 40200 Shah Alam Selangor Darul Ehsan Malaysia https www panasonic com DH 6SM1_PH indb 12 DH 6SM1_PH indb 12 1 27 2021 12 55 14 PM 1 27 2021 12 55 14 PM ...

Reviews: