background image

DH940A3PL1PA

Operating and Installation Instructions

Electric Home Shower (Household Use)

Thank you for purchasing the Panasonic Electric Home Shower. This appliance is intended for household use only.

For optimum performance and safety, please carefully read this Operating Instructions and keep this documentation

in a safe place for future reference.

DH-3PL1

Model No.

OP

EN

CL

OS

E

FILTER

CLEANING

ELB Test

ELB Reset

Push Up

OFF

MAX

Pow

e

r Contr

ol

Main

 Switch

ELB

Off

Off

High

On

Summary of Contents for DH-3PL1PH

Page 1: ...e Shower This appliance is intended for household use only For optimum performance and safety please carefully read this Operating Instructions and keep this documentation in a safe place for future reference DH 3PL1 Model No O P E N C L O S E FILTER CLEANING ELB Test ELB Reset Push Up OFF MAX Power Control Main Switch ELB Off Off High On ...

Page 2: ...carefully To prevent personal injury injury to others and property damage the following instructions must be followed Incorrect operation caused by failure to follow instructions will cause harm or damage the seriousness of which is classified as follow SAFETY INSTRUCTIONS To be followed absolutely CONTENTS Page No BEFORE USING ELECTRIC HOME SHOWER 1 SAFETY INSTRUCTIONS 2 PARTS IDENTIFICATION 3 AC...

Page 3: ...ectric home shower Unit to avoid physical and electric shock hazards If the ELB Reset Lever cannot be reset even if you push it up or if it soon slides down during operation please do not use the Unit and contact the authorized dealer immediately to avoid a hazard to users such as damage to property serious injury or death Never fix the ELB Reset Lever forcibly with tape and such Do not replace th...

Page 4: ...Filter Body Packing OPEN C L O S E FILTE R CLEANIN G OFF MA X O P EN C L O S E FIL TE R CLE AN ING O F F M A X O P E N C L O S E FILTER CLEANING OFF MAX ELB Test ELB Reset Push Up Power Control Main Switch ELB Off Off High On O P E N C L O S E FILTER CLEANING OFF MAX ELB Lamp Filter Body Assembly Installation การติดตั งชิ นส วนประกอบตัวเครื องกรอง Place Rubber Packing between Filter Body Assembly ...

Page 5: ...alve Step 1 Turn OFF the Main Water Valve Step 2 Turn the Shower Head upward at waist height Step 3 Turn the Water Volume Knob clockwise to maximum volume position Step 4 Gradually turn ON the Main Water Valve and adjust the splashing height H of the shower It is recommended to adjust the water splashing height H at 100 cm 110 cm approximately 3 L min Note 1 After setting maximum flow rate please ...

Page 6: ...an it with moist cloth 2 Never use benzene thinner detergent bleach and such 3 Do not spray water to the Unit nor put wet towels on it 4 Make sure to use suitable cloth to clean the Front Plate surface to avoid scratch 2 Shower Head cleaning Turn the Shower Plate anticlockwise and remove it from the Shower Head with hand Clean the Shower Head s holes by using a soft brush from time to time Recomme...

Page 7: ... down Push up the ELB Reset Lever to reset the ELB refer to TEST OPERATION at page 11 3 Make sure to switch on the ON OFF DP double pole Switch 4 Make sure to switch on the Miniature Circuit Breaker MCB 1 Check the Water Volume Knob Turn the Water Volume Knob clockwise if it is closed 2 Check the Main Water Valve Turn ON the Main Water Valve if it is closed refer to HOW TO USE at page 5 1 Check th...

Page 8: ...outlet inlet water cannot be filtered and allows foreign particles to enter the Unit It will cause Heater Unit and Shower Head to clog up Do not install remove and reinstall the Unit by yourself Improper installation will cause leakage electric shock or fire Installation and wiring must be done by competent personnel Do not share the inlet and outlet pipe of the Home Shower Unit with other outlets...

Page 9: ... N to the ELB L N and earth wire to the Ground Point with 1 N m 10 kgf cm torque Fix back the Cord Holder to its position to clamp the Flexible Cord Connect wires in correct polarity L N Connecting the wires in wrong polarity L N causes an abnormal condition which may lead to electric leaking burning and such Before wiring please check polarity L N with voltage range of a tester or voltmeter by co...

Page 10: ...all or tiles If the Adjust Holder needs to be cut due to different wall height make sure the Adjust Holder is touching to the wall or tiles to prevent possibility of water leakage at the Filter Body Assembly Touching to the wall tiles wall tiles Touching to the wall tiles tiles tiles Cut Adjust Holder About 5 mm The Unit must be earthed Earth Rod fixing procedure Select suitable place to bury the ...

Page 11: ...ng to the sequence as illustrated Push in the Main Switch Knob and Power Control Knob until it is fully inserted Main Switch Knob and Power Control Knob can not be inserted if Step and Step is not done accordingly Fix the screw at the bottom of the Unit Note 1 Do not push the ELB Test Button during fixing the Front Plate 2 Do not apply extreme force to insert the Main Switch Knob and Power Control...

Page 12: ... Manufacturing Malaysia Berhad 2019 H0919Z1 20621 Panasonic Manufacturing Malaysia Berhad 196501000304 No 3 Jalan Sesiku 15 2 Section 15 Shah Alam Industrial Site 40200 Shah Alam Selangor Darul Ehsan Malaysia http www panasonic com ...

Reviews: