- 18 -
1.5 m ~ 1.7 m
2. HOW TO INSTALL
Main Pipe
Rising Level
* Maximum total length of feeding pipe
should be below 10 m.
* The feeding pipe should be 1/2 inch.
33ft (10 meters) maximum
recommended height between
bottom of cold water tank and top
of shower units.
Cold Water
Tank
Service
Valve
Figure 1
Figure 2
Note: When removing the Unit from package, some water may be found inside.
This is normal as the Unit is tested during the manufacturing process.
(1) Make sure water flow pressure.
Min. water pressure
4.9 kPa / 0.05 k
g
f/cm² / 0.7 psi
Max. water pressure
380 kPa / 3.87 k
g
f/cm² / 55 psi
•
How to measure the water pressure as illustrated. Water should flow out of the
Hose 2.0 m above the Main Water Valve.
1. BEFORE INSTALLATION
2.0 m
HOW TO INSTALL ELECTRIC HOME SHOWER
Water Inlet
Water Outlet
Water
Volume
Knob
•
Flexible Cord must enter the Unit thru designated point only (do not make additional holes).
•
Proper size of Flexible Cord and electric wiring must be installed to avoid smoke emission and fire hazards.
•
During installation process make sure electric and water supply is turn "OFF".
•
The home shower must be permanently connected to the electric supply through the ON/OFF DP (double
pole) Switch having a contact separation of at least 3 mm in all poles incorporated in the fixed wiring. This
switch must be clearly identifiable but out of reach of a person using a fixed bath or shower.
The Unit must be earthed.
Improper grounding could cause electric shock.
•
Never install Filter Body Assembly at the outlet, inlet water cannot be filtered and allows
foreign particles to enter the Unit. It will cause Heater Unit and Shower Head to clog up.
•
Do not install, remove and reinstall the Unit by yourself.
Improper installation will cause leakage, electric shock or fire. Installation and wiring must be
done by competent personnel.
•
Do not share the inlet and outlet pipe of the Home Shower Unit with other outlets.
The pressure may drop due to water being drawn off at other point. The shower temperature
may become very hot.
During installation process make sure
electric and water supply is turn "OFF".
WARNING
1. Where to install the Unit.
• Be sure to install the Unit on the wall as illustrated in
Figure 1 (vertical condition only).
• Do not install the Unit away from wall surface as shown
in Figure 2.
• The Unit must be installed at 1.5 m ~ 1.7 m above the
floor.
JET PUMP
DH-3MP1
ELB Reset
Push Up
ELB Test
Push On-Off
Power Control
Off
ELB
High
JET PUMP
DH-3MP1
ELB Reset
Push Up
ELB Test
Push On-Off
Power Control
Off
ELB