background image

11/15

*This installation is omitted at the second and all subsequent connections.

However, for PCs with multiple USB ports, this recognition/setting change window may appear 

again if you insert the USB cable into another USB port and switch the power on. If this 
happens, install using the same procedure.

*The connecting Wizard may appear this time or every time, depending on the Wizard. In any 
case, please follow the same procedure.

7)  Completing the Found New Hardware Wizard is displayed in the Found New Hardware 
Wizard, and the install is complete.

1) If the image display software is running on the PC, stop the display, and

close the image display program.

2) Disconnect the 3D image sensor power supply and the USB.

8.2 Shutdown Procedure

* Turn OFF the power supply of the 3D image sensor while the PC power is still on.

Summary of Contents for D-IMager EKL3104

Page 1: ...1 15 3D Image Sensor Model No EKL3104 User s Manual 2010 9 30 Version 1 20 ...

Page 2: ...2 6 14 6 7 13 This manual and the software are copyrighted by Panasonic Electric Works Co Ltd Reproduction of this manual in any form without prior approval is strictly prohibited Windows and Windows Vista are registered trademarks of Microsoft Corporation in the United States and or other countries Pentium is registered trademarks of Intel Corporationin the United States and or other countries Su...

Page 3: ... This product is designed for indoor use Do not use it in any outdoor environment or in places where it could be in contact with water 5 Always connect the sensor unit USB AC adaptor before plugging in the power supply 6 Always use an AC adaptor as specified on page 7 and ensure it is properly connected Incorrect connections may cause malfunctions generate abnormal high levels of heat emit smoke e...

Page 4: ...n at the outline of the target 4 Distance from wall or floor If wall or floor is close to the sensor closer than 1 2 m 3 94ft it may produce distance measuring errors from reflection ofemitted near infrared rays 5 Other precautions The range resolution may diminish depending on the target s reflectance distance to the sensor or position 1 This product is destined for indoor use only Do not install...

Page 5: ...zine aromatic liquid pesticides etc on the product 4 Maintenance 7 FCC Compliance Statement This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and f...

Page 6: ...w Password for software download The below software and manuals can be downloaded on the official home page USB Drivers XP Vista Dimagerusb inf Dimagerusb sys Range Image Display Software DigiCapUSB exe Library for Application Software Development Dimagerdll h Dimagerdll lib Dimagerdll dll User s Manual this document Instruction Manual for library Dimagerdll dll 6 Parts Name Fall prevention wire f...

Page 7: ... 2 0 port PC USB2 0 cable AC Adaptor USB mini B type 3D Image sensor Sensor Unit AC Power Supply Cable Note 1 Depending on the network environment or other applications etc the sensor may not function Note 2 If you use simultaneously an other USB connected device this product may not function properly EIAJ RC 5320A Voltage class5 7 2 Connection Example M4 Screw depth 6 0mm 0 236inch W1 4 Screw dep...

Page 8: ...ng the sensor unit in high places Please work with care in high place 1 Wrap the wire around a secure place that could stop a fall and insert one extremity s ring into the other 2 Attach the ring that went through the other to the gutter located at the upper left of the sensor unit 3 Place the provided washer above it and fix it with the provided M3 screw Do not press down too strongly the washer ...

Page 9: ...izard will appear on the PC screen only when the main unit is connected and has been started up the first time Please install according to the given procedure The connecting Wizard may appear this time or every time depending on the Wizard In any case please follow the same procedure 8 1 Startup Procedure 4 Select Install from a list or specific location Advanced and click Next The following scree...

Page 10: ...aded Dimagerusb ini and Dimagerusb sys and click Next The screen shows an example where the above files are stored in the C Dimager folder 6 Found New Hardware Wizard is displayed and then hardware Installation is displayed Click Continue Anyway ...

Page 11: ...connecting Wizard may appear this time or every time depending on the Wizard In any case please follow the same procedure 7 Completing the Found New Hardware Wizard is displayed in the Found New Hardware Wizard and the install is complete 1 If the image display software is running on the PC stop the display and close the image display program 2 Disconnect the 3D image sensor power supply and the U...

Page 12: ...the application software Please note characteristics is changed per the frame rate Range Resolution 1 σ 3cm 1 57inch max Ambient Illumination 0lx 2 σ 14cm 11 81inch max Ambient Illumination 20 000lx Measuring Conditions Ambient temperature 25 77 F distance 2m 6 56ft 90 near infrared reflectance target object at central pixel 20fps Depend on the environment and distance Absolute accuracy 4cm 1 57in...

Page 13: ...rted to such country 4 In the event CUSTOMER breaches any provision of this Article CUSTOMER shall be liable for any and all direct and indirect damages incurred by Panasonic Electric Works Co Ltd PEW arising from such breach and notwithstanding anything herein contained to the contrary PEW shall have the right to terminate this AGREEMENT forthwith without any liability to CUSTOMER Furthermore PEW...

Page 14: ...and the specifications sheet We will replace any malfunctioning product if such defect or malfunction is caused by us However the above warranty shall be void in the following circumstances a Damage caused to something else than the product itself b Resulting from misuse of the product use not in accordance with the precautions mentioned above and this specifications sheet c Resulting from a fall ...

Page 15: ...2 H DC110V F HC4 H DC24V HL2 HTM DC24V F HL2 HTM AC24V F HC4 H AC24V HC4 H AC120V HC4 H DC12V AZH2031 RP SDMF64DA1 EVM F6SA00B55 RP SMLE08DA1 ERZ V20R391 ELL ATV681M LC R121R3P ERZ V05V680CB LT4H DC24V LT4HL8 AC24V LT4HW AC24V LT4HWT8 AC240V LT4HWT AC240VS CY 122A P ETQ P5M470YFM EVAL_PAN1555 EVQ PAE04M EX 14B EX 22B PN EX 31A C5 EXB 24N121JX EX F72 PN EX L211 EYG A121803V FCR M50 AC208V FC SFBH 2...

Reviews: