SELECT THE BEST LOCATION
INDOOR UNIT
ı
ı
ı
ı
ı
ı
OUTDOOR UNIT
Indoor/Outdoor Unit Installation Diagram
- 31 -
CS-PW9DKE / CU-PW9DKE / CS-PW12DKE / CU-PW12DKE
Attached accessories.
1
No.
Accessories part
Qty. No.
Accessories part
Qty.
1
2
3
4
Installation plate
Installation plate fixing
screw
Remote control
Battery
1
5
1
2
5
Drain elbow
1
6
Connecting Wire (Connector)
Indoor/Outdoor Unit Installation Diagram
About 1.1 m
Piping direction
Attention not to
bend up drain hose
Length of power supply cord
Right
Right Bottom
Right Rear
Left
Rear
Left Bottom
Left
(Front side)
About 1.8 m
<
<
<
<
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall,
ceiling, fence or other obstacles.
Recommended installation height for indoor unit shall
be at least 2.5 m.
ı
There should not be any heat source or steam near
the unit.
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
There should not be any animal or plant which could
be affected by hot air discharged.
Keep the spaces indicated by arrows from wall,
ceiling, fence or other obstacles.
Do not place any obstacles which may cause a short
circuit of the discharged air.
If piping length is over the common length, additional
refrigerant should be added as shown in the table.
Model
PW9DKE
PW12DKE
Piping size
Max. Piping
Length
(m)
10
15
Common
Length
(m)
7.5
7.5
Max.
Elevation
(m)
5
5
Additional
Refrigerant
(g/m)
20
20
Gas
3/8"
3/8"
Liquid
1/4"
1/4"
This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
Installation plate
1
Sleeve ( )
Bushing Sleeve ( )
Putty (Gum type sealer) ( )
Vinyl tape (Wide) ( )
Apply after carrying out a
drainage test.
To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
Saddle ( )
5-CORE WIRE/1.5 mm
2
Type designation 245 IEC 57
or heavier cord
Additional drain hose ( )
Bend the pipe as closely on
the wall as possible, but be
careful that it doesn t break.
Installation parts you
should purchase ( )
Gas side piping ( ) 3/8"
1/4" Liquid side piping ( )
10 cm
or more
10
cm
or
mor
e
100
cm
or more
Connecting cable
5c
m
or
more
5 cm
or more
30
cm
or more
(Left and right are identical)
Insulation of piping connections
Carry out insulation
after checking for
gas leaks and
secure with vinyl
tape.
Vinyl tape