20.2 Heat Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Heat mode at 30°C Voltage: 230V
20.2.1 CS-Z25UFEAW CU-Z25UBEA
Indoor (°C)
Outdoor WB (°C)
DB
-15 -7 2
7 12
TC IP TC IP TC IP TC IP TC IP
24 2130 1067 2717 1165 3445 1216 3102 762 3007 613
20 2260 1060 2880 1180 3620 1190 3400 760 3555 737
16 2456 1030 2754 1117 3573 1102 3565 763 3835 760
20.2.2 CS-Z35UFEAW CU-Z35UBEA
Indoor (°C)
Outdoor WB (°C)
DB
-15 -7 2
7 12
TC IP TC IP TC IP TC IP TC IP
24 2554 1188 3180 1392 4140 1584 3923 1083 3803 871
20 2710 1180 3370 1410 4350 1550 4300 1080 4496 1047
16 2945 1146 3223 1335 4294 1435 4509 1084 4851 1080
20.2.3 CS-Z50UFEAW CU-Z50UBEA
Indoor (°C)
Outdoor WB (°C)
DB
-15 -7 2
7 12
TC IP TC IP TC IP TC IP TC IP
24 3534 1792 4746 2034 5586 2361 5292 1555 5130 1250
20 3750 1780 5030 2060 5870 2300 5800 1550 6065 1502
16 4076 1729 4810 1950 5794 2129 6081 1556 6543 1550
TC - Total Heating Capacity (W)
IP - Input Power (W)