11
3. Specifications
Model
Indoor CS-Z25UFEAW
CS-Z35UFEAW
Outdoor CU-Z25UBEA
CU-Z35UBEA
Performance Test Condition
EUROVENT
EUROVENT
Power Supply
Phase, Hz
Single, 50
Single, 50
V 230
230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW
0.85 2.50 3.40 0.85 3.50 3.80
BTU/h
2900 8530 11600 2900 11900 13000
kcal/h
730 2150 2920 730 3010 3270
Running
Current
A
– 2.50 – – 3.90 –
Input
Power
W
240 520 900 240 860 1.02k
Annual
Consumption kWh
– 260 – – 430 –
EER
W/W
3.54 4.81 3.78 3.54 4.07 3.73
BTU/hW 12.08 16.40 12.89 12.08 13.84 12.75
kcal/hW 3.04 4.13 3.24 3.04 3.50 3.21
ErP
Pdesign kW
2.5
3.5
SEER (W/W)
7.9
8.1
Annual
Consumption
kWh 111
151
Class
A++
A++
Power
Factor
%
– 90 – – 96 –
Indoor Noise (H / L / QLo)
dB-A
38 / 25 / 20
39 / 26 / 20
Power Level dB
54 / – / –
55 / – / –
Outdoor Noise (H / L / QLo)
dB-A
46 / – / –
48 / – / –
Power Level dB
61 / – / –
63 / – / –
Heating
Capacity
kW
0.85 3.40 5.00 0.85 4.30 6.00
BTU/h
2900 11600 17100 2900 14700 20500
kcal/h
730 2920 4300 730 3700 5160
Running
Current
A
– 3.50 – – 4.80 –
Input
Power
W
240 760 1.35k 240 1.08k 1.75k
COP
W/W
3.54 4.47 3.70 3.54 3.98 3.43
BTU/hW 12.08 15.26 12.67 12.08 13.61 11.71
kcal/hW 3.04 3.84 3.19 3.04 3.43 2.95
ErP
Pdesign kW
2.7
3.2
Tbivalent °C
-10
-10
SCOP (W/W)
4.6
4.6
Annual
Consumption
kWh 822
974
Class
A++
A++
Power
Factor
%
– 94 – – 98 –
Indoor Noise (H / L / QLo)
dB-A
38 / 25 / 19
39 / 26 / 19
Power Level dB
54 / – / –
55 / – / –
Outdoor Noise (H / L / QLo)
dB-A
47 / – / –
48 / – / –
Power Level dB
62 / – / –
63 / – / –
Low Temp. : Capacity (kW) / I.Power (W) / COP
3.62 / 1.19k / 3.04
4.35 / 1.55k / 2.81
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
2.88 / 1.18k / 2.44
3.37 / 1.41k / 2.39
Max Current (A) / Max Input Power (W)
6.2 / 1.35k
8.0 / 1.75k
Starting Current (A)
3.50
4.80