90
Remote Control Receiving Sound
o
Normal
Operation
nanoe Operation
: Beep
o
nanoe
Operation
Normal Operation
: Beep
o
Stop
nanoe individual Operation : Beep
o
nanoe individual Operation
Stop
: Long Beep
Power
failure
o
During nanoe individual operation, if power failure occurs, after power resumes, nanoe individual operation
resumes immediately.
o
During combination operation, if power failure occurs, after power resumes, combination operation resume
immediately.
nanoe
check
mode
o
To enable nanoe check mode, during nanoe operation ON:
Normal display mode
Transmit
“NANOE CHECK” code
Press SW
(t
≥
0 secs)
When
SW pressed continuously for t
≥
5 secs to enter service zone
and press
SW’s to choose function 57
o
During nanoe check mode, H67 is judged when disconnection detected. Timer LED blinks.
nanoe Abnormal Detection
o
Disconnection
Abnormality
Abnormal
detection
condition
Start from 1 sec after nanoe power ON, 6 secs has passed and in this 6 secs period, abnormal signal
is detected continuously for 5.9 secs.
Action after abnormal detection condition fulfilled
Disconnection co1, nanoe power OFF for 5 minutes and then restart. However, according to
action mode and disconnection counter, below will be implemented:
o
During nanoe Check Mode: Disconnection abnormality will judged when disconnection counter
≥
1. Abnormal code: H67 will memorized in EEPROM, Timer LED blinking and nanoe LED Off.
o
Other Than Above: Disconnection abnormality will judged when disconnection counter
≥
3.
Abnormal code: H67 will memorized in EEPROM and nanoe LED OFF, Timer LED not blinking.
Disconnection counters clear condition >
Disconnection counter will be cleared when operation stop. (Not nanoe Check Mode)
AMP Air Conditioning