Troubleshooting
The following symptoms do not indicate malfunction.
Symptom
Cause
POWER indicator blinks before the unit
is switched on.
• This is a preliminary step in preparation for the
operation when the ON timer has been set.
• When ON Timer is set, the unit may start earlier
(up to 15 minutes) before the actual set time in
order to achieve the desired temperature on time.
TIMER indicator is always on.
• The timer setting repeats daily once set.
Operation is delayed a few minutes after
restarting.
• The delay is a protection to the unit’s
compressor.
Indoor fan stops occasionally during
automatic fan speed setting.
• This helps to remove the surrounding odour.
The room has a peculiar odour.
• This may be due to damp smell emitted by the
wall, carpet, furniture or clothing.
Cracking sound during operation.
• Changes of temperature caused the expansion/
contraction of the unit.
Water fl owing sound during operation.
• Refrigerant fl ow inside the unit.
Mist emerges from indoor unit.
• Condensation eff ect due to cooling process.
Outdoor unit emits water/steam.
• Condensation or evaporation occurs on pipes.
Louder noise at outdoor unit during early
operation of i AUTO-X.
• The compressor and fan rotate at higher speed to
boost cooling performance during initial operation.
Discoloration of some plastic parts.
• Discoloration is subject to material types used in
plastic parts, accelerated when exposed to heat,
sun light, UV light or environmental factor.
Dust may have collected around the front
panel, grilles and wall surrounding the
unit after extended use.
• The dust accumulation is due to air purifi cation
eff ect of negative ions from nanoe-G. Remove
the dust regularly with a clean dampened cloth.
Check the following before calling for servicing.
Symptom
Check
Operation in COOL mode is not working
effi ciently.
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet
vents.
Noisy during operation.
• Check if the unit has been installed at an incline.
• Close the front panel properly.
Remote control does not work.
(Display is dim or transmission signal is
weak.)
• Insert the batteries correctly.
• Replace weak batteries.
The unit does not work.
• Check if the circuit breaker is tripped.
• Check if timers have been set.
The unit does not receive the signal from
the remote control.
• Make sure the receiver is not obstructed.
• Certain fl uorescent lights may interfere with signal
transmitter. Please consult authorised dealer.