Operation mode

i AUTO-X :

The fast cooling is ideal when you come home on a hot day.

COOL

:

Provides effi  cient comfort cooling to suit your needs.

DRY

:

Unit operates at low fan speed to give a gentle cooling operation.

nanoe-G in-fi lter deactivation

Depending on the unit’s accumulated operation time, nanoe-G in-fi lter deactivation may be 

activated only once a day after the unit turned off .
To remove the moisture left in the internal parts, the fan will operate for 30 minutes with fl ap 

opened slightly. This process only applicable when the unit is operated in COOL/DRY mode 

before turned off . Then, nanoe-G deactivates viruses/bacteria on the fi lter for 2 hours with fan 

stopped and fl ap closed.
Do not turn off  the power supply during this operation. After power failure, this operation will 

not resume.

Energy saving temperature setting

Operating the unit within the recommended temperature range may save energy.

COOL : 

26.0 °C ~ 28.0 °C / 79 °F ~ 82 °F. 

Air fl ow direction

In COOL/DRY mode:

If AUTO is set, the fl ap swings left/right and up/down automatically.

In i AUTO-X mode:

If AUTO is set, the horizontal flap is fixed at the lower position and shift to upper position after 

reaches set temperature. If manual is set, the horizontal flap and vertical fl ap are fixed at the 

predetermined position.

Auto restart control

If power is resumed after a power failure, the operation will restart automatically after a 

period of time with previous operation mode and airfl ow direction.

• This control is not applicable when TIMER is set.

Operating conditions

Use this air conditioner in the temperature range indicated in the table.

Temperature °C (°F)

Indoor

Outdoor

DBT

WBT

DBT

WBT

COOL

Max.

32 (89.6)

23 (73.4)

43 (109.4)

26 (78.8)

Min.

16 (60.8)

11 (51.8)

16 (60.8)

11 (51.8)

DBT : Dry bulb temperature, WBT : Wet bulb temperature

To learn more...

ACXF55-17630_YZ0218-0.indb   32

ACXF55-17630_YZ0218-0.indb   32

1/9/2018   2:24:56 PM

1/9/2018   2:24:56 PM

Summary of Contents for CS-XU9UKH-8

Page 1: ...s ng b i ng i l p t tr c khi l p t i u khi n t xa c ng g i c ng v i d n l nh v c g b b i ng i l p t tr c khi l p t Operating Instructions Air Conditioner 20 37 Before operating the unit please read t...

Page 2: ...ng 5 gi y hi n th th i gian theo 12 gi am pm ho c 24 gi 2 X c nh n SET S d ng i u khi n trong kho ng 8 m t t nh t i u khi n n thi t b 2 t i u khi n n thi t b AIR CONDITIONER ON OFF SET TIMER CANCEL O...

Page 3: ...t mong mu n L n Xu ng TEMP D i nhi t l a ch n 16 0 C 30 0 C 60 F 86 F Nh n v gi n t trong kho ng 10 gi y chuy n n v nhi t t C ho c F C m n b n l a ch n M y i u h a kh ng kh Panasonic Ti ng Vi t N i du...

Page 4: ...t v x l kh ng ng c th g y r ga i n gi t ch y n Vui l ng ki m tra l i v i i l y quy n ho c chuy n gia v lo i ch t l nh s d ng Vi c s d ng c c lo i ch t l m l nh kh c c th l m h ng s n ph m ch y n ho c...

Page 5: ...ng Kh ng t c c thi t b d ch y tr c ng gi th i ra tr nh ch y n Kh ng gi l nh th i tr c ti p v o c y c nh hay v t nu i tr nh g y th ng t ch ho c h h i Kh ng ch m v o c nh s c c a l nh m c nh s c c th g...

Page 6: ...g T ng t khi b o qu n ng ng c n b c k n u h b ng k p d y bu c b o qu n R32 gi ng nh b o qu n R410A Vi c v n h nh b o d ng s a ch a v ph c h i m i ch t l m l nh ph i c ti n h nh b i c c nh n vi n c o t...

Page 7: ...n ngh c a nh s n xu t 2 2 Ti n h nh c ng vi c Tr c khi ti n h nh l m vi c tr n c c h th ng ch a m i ch t l m l nh d ch y c n tri n khai c ng t c ki m tra an to n m b o r ng m i r i ro ch y m c th p n...

Page 8: ...i ch t l m l nh tr khi c c b ph n n y c ch t o t v t li u v n c kh n ng ch ng n m n ho c c b o v c bi t ch ng l i t c nh n n m n 2 8 Ki m tra c c thi t b i n Vi c s a ch a v b o tr c c thi t b i n ph...

Page 9: ...n x c nh n t l kh ga ph h p t i a l 25 Ch t l ng ph t hi n r r ph i ph h p v i h u h t c c m i ch t l m l nh c d ng nh ng n n tr nh s d ng c c ch t t y r a c ch a Clo b i nguy n t n y c th ph n ng v i...

Page 10: ...ng 24 24 thi t b v xi lanh d ng thu m i ch t ph i p ng m i ti u chu n theo quy nh d N u c th b m v i h th ng ch t l m l nh e N u kh ng th t o ra kho ng ch n kh ng c n l p i l p l i c c ho t ng tr n c...

Page 11: ...o ki n t v n c a nh s n xu t M i ch t c thu h i s c g i l i cho nh cung c p sau khi c ng trong c c xi lanh ph h p v d n nh n Ch V n chuy n R c th i li n quan Kh ng l n c c m i ch t trong c c thi t b...

Page 12: ...h p n y t c c a c nh o gi v qu t s ho t ng theo c i t c a i u khi n t xa N u m t i n khi m y ang ch y ch s c ph c h i ngay khi c i n tr l i ch AUTO T NG t c qu t s c t ng i u ch nh theo ch ho t ng N...

Page 13: ...h c nhau M y ki m so t nhi t d a theo nhi t ph ng t ng t c l m m t ph ng Sau t i a 4 gi nhi t s c t theo l n thi t l p cu i c ng T c qu t c c nh AUTO nghi m c m l a ch n t c qu t Trong khi m y t t nh...

Page 14: ...i nhi t khuy n c o ti t ki m i n COOL 26 0 C 28 0 C 79 F 82 F H ng gi ch COOL DRY L M L NH H T M N u l ch AUTO T NG c nh o gi s chuy n ng theo h ng tr i ph i v l n xu ng m t c ch t ng ch i AUTO X N u...

Page 15: ...g 1 l n b i c c i l y quy n Kh i ngo i tr i D n s ch r c xung quanh m y L m s ch ng d n n c L i l c kh 2 tu n m t l n R a tr ng l i l c nh nh ng tr nh l m h b m t l i l c Ph i kh l i l c trong b ng r...

Page 16: ...m u m t s linh ki n b ng nh a S b c m u t y thu c v o v t li u c s d ng trong c c linh ki n b ng nh a s b b c m u nhanh h n khi ti p x c v i nhi t nh s ng m t tr i tia c c t m ho c y u t m i tr ng B i...

Page 17: ...gi v o v c a gi ra nh d i y c ngh a l m y ho t ng b nh th ng COOL 8 C 14 4 F M y s kh ng c s d ng trong m t th i gian d i K ch ho t ch c n ng nanoe TECHNOLOGY trong 2 3 gi nh m t c ch lo i tr m c n s...

Page 18: ...trong nh ngo i tr i kh ng k t n i v i nhau H 34 C m bi n nhi t b l m m t kh i ngo i tr i c v n H 35 D ng i n ng c chi u c a kh i trong ngo i tr i c v n H 36 C m bi n nhi t ng d n gas kh i ngo i tr i c...

Page 19: ...t h p v i m t k hi u h a h c Trong tr ng h p n y n tu n th c c quy nh c li n quan v h a ch t WARNING Bi u t ng n y cho bi t thi t b d ng m i ch t l m l nh d ch y N u m i ch t l m l nh b r r c ng l c...

Page 20: ...roximately 5 seconds to show time in 12 hour am pm or 24 hour indication 2 Con rm SET Use remote control within 8 m from the remote control receiver of the indoor unit 20 control receiver of the indoo...

Page 21: ...Up Down TEMP Selection range 16 0 C 30 0 C 60 F 86 F Press and hold for approximately 10 seconds to switch the temperature indication in C or F Thank you for purchasing Panasonic Air Conditioner The...

Page 22: ...g will cause leakage electric shock or re Con rm with authorised dealer or specialist on usage of any speci ed refrigerant type Using refrigerant type other than the speci ed may cause product damage...

Page 23: ...lity deterioration etc Do not use any combustible equipment in front of the air ow outlet to avoid re propagation Do not expose plants or pet directly to air ow to avoid injury etc Do not touch the sh...

Page 24: ...ping securely seal the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certi ed personn...

Page 25: ...on competent in the use of ammable refrigerants Servicing shall be performed only as recommended by the manufacturer 2 2 Work Prior to beginning work on systems containing ammable refrigerants safety...

Page 26: ...ly resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks...

Page 27: ...ge of gas 25 maximum is con rmed Leak detection uids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refri...

Page 28: ...standards d Pump down refrigerant system if possible e If a vacuum is not possible make a manifold so that refrigerant can be removed from various parts of the system f Make sure that cylinder is sit...

Page 29: ...release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant Waste Transfer Note arranged Do not...

Page 30: ...ap and fan speed will operate based on remote control setting If power failure occurs during this operation this operation will be resumes immediately after power resumes For AUTO the indoor fan speed...

Page 31: ...temperature according to room temperature to accelerate room cooling After max 4 hours the set temperature follows the last set temperature setting Fan speed is xed at AUTO fan speed selection is proh...

Page 32: ...unit within the recommended temperature range may save energy COOL 26 0 C 28 0 C 79 F 82 F Air ow direction In COOL DRY mode If AUTO is set the ap swings left right and up down automatically In i AUTO...

Page 33: ...Outdoor unit Clear debris that surround the unit Clear any blockage from drain pipe Air lters Once every 2 weeks Wash rinse the lters gently with water to avoid damage to the lter surface Dry the lte...

Page 34: ...at higher speed to boost cooling performance during initial operation Discoloration of some plastic parts Discoloration is subject to material types used in plastic parts accelerated when exposed to h...

Page 35: ...l to have the following temperature di erence between the air inlet and outlet vents COOL 8 C 14 4 F The units are not going to be used for a long period of time Activate nanoe TECHNOLOGY mode for 2 3...

Page 36: ...ure sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor ou...

Page 37: ...complies with the requirement set by the Directive for the chemical involved Troubleshooting Information WARNING This symbol shows that this equipment uses a ammable refrigerant If the refrigerant is...

Page 38: ...Memo ACXF55 17630_YZ0218 0 indb 38 ACXF55 17630_YZ0218 0 indb 38 1 9 2018 2 24 58 PM 1 9 2018 2 24 58 PM...

Page 39: ...Memo ACXF55 17630_YZ0218 0 indb 39 ACXF55 17630_YZ0218 0 indb 39 1 9 2018 2 24 58 PM 1 9 2018 2 24 58 PM...

Page 40: ...Corporation 1006 Kadoma Kadoma City Osaka Japan Website http www panasonic com Panasonic Corporation 2018 ACXF55 17630 YZ0218 0 ACXF55 17630_YZ0218 0 indb 40 ACXF55 17630_YZ0218 0 indb 40 1 9 2018 2...

Reviews: