Error Codes Table
Diagnosis
display
Abnormality / Protection control
Abnormality
Judgement
Emergency
operation
Primary location to verify
H11
Indoor / outdoor abnormal
communication
> 1 min after starting
operation
Indoor fan operation
only
•
•
•
•
Internal / external cable connections
•
•
•
•
Indoor / Outdoor PCB
H14
Indoor intake air temperature sensor
abnormality
—
—
•
•
•
•
Intake air temperature sensor
(defective or disconnected)
H15
Outdoor compressor temperature sensor
abnormality
Continue for 5 sec.
—
•
•
•
•
Compressor temperature sensor
(defective or disconnected)
H16
Outdoor Current Transformer open
circuit
—
—
•
•
•
•
Outdoor PCB
•
•
•
•
IPM (Power transistor) module
H19
Indoor fan motor merchanism lock
—
—
•
•
•
•
Indoor PCB
•
•
•
•
Fan motor
H23
Indoor heat exchanger temperature
sensor abnormality
Continue for 5 sec.
O
(Cooling only)
•
•
•
•
Heat exchanger temperature sensor
(defective or disconnected)
H26
Ionizer abnormality
—
—
•
•
•
•
Indoor PCB
•
•
•
•
Ionizer
H27
Outdoor air temperature sensor
abnormality
Continue for 5 sec.
O
•
•
•
•
Outdoor temperature sensor
(defective or disconnected)
H28
Outdoor heat exchanger temperature
sensor abnormality
Continue for 5 sec.
O
•
•
•
•
Outdoor heat exchanger
temperature sensor (defective or
disconnected)
H33
Indoor/Outdoor wrong connection
—
—
•
•
•
•
Indoor/Outdoor supply voltage
H97
Outdoor Fan Motor lock abnormality
—
—
•
•
•
•
Outdoor PCB
•
•
•
•
Outdoor Fan Motor
H98
Indoor high pressure protection
—
—
•
•
•
•
Air filter dirty
•
•
•
•
Air circulation short circuit
H99
Indoor heat exchanger anti-freezing
protection
—
—
•
•
•
•
Insufficient refrigerant
•
•
•
•
Air filter dirty
F11
Cooling / Heating cycle changeover
abnormality
4 times occurance
within 30 minutes
—
•
•
•
•
4-way valve
•
•
•
•
V-coil
F91
Refrigeration cycle abnormality
2 times occurance
within 20 minutes
—
•
•
•
•
No refrigerant
(3-way valve is closed)
F93
Outdoor compressor abnormal revolution
4 times occurance
within 20 minutes
—
•
•
•
•
Outdoor compressor
F95
Cool high pressure protection
4 times occurance
within 20 minutes
—
•
•
•
•
Outdoor refrigerant circuit
F96
IPM (power transistor) overheating
protection
—
—
•
•
•
•
Excess refrigerant
•
•
•
•
Improper heat radiation
•
•
•
•
IPM (Power transistor)
F97
Outdoor compressor overheating
protection
4 times occurance
within 10 minutes
—
•
•
•
•
Insufficient refrigerant
•
•
•
•
Compressor
F98
Total running current protection
3 times occurance
within 20 minutes
—
•
•
•
•
Excess refrigerant
•
•
•
•
Improper heat radiation
F99
Outdoor Direct Current (DC) peak
detection
7 times occurance
continuously
—
•
•
•
•
Outdoor PCB
•
•
•
•
IPM (Power transistor)
•
•
•
•
Compressor
Note:
“O” - Frequency measured and fan speed fixed.
The memory data of error code is erased when the power supply is cut off, or press the Auto Switch until “beep” sound heard
following by pressing the “RESET” button at remote controller.
Although operation forced to stop when abnormality detected, emergency operation is possible for certain errors (refer to Error
Codes Table) by using remote controller or Auto Switch at indoor unit. However, the remote controller signal receiving sound is
changed from one “beep” to four “beep” sounds.
85
CS-XE9CKE CU-XE9CKE / CS-XE12CKE CU-XE12CKE
Summary of Contents for CS-XE9CKE
Page 10: ...4 Dimensions 10 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 11: ...11 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 12: ...5 Refrigeration Cycle Diagram 12 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 13: ...6 Block Diagram 13 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 14: ...7 Wiring Diagram 14 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 91: ...13 Technical Data 91 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 92: ...92 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 104: ...104 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 105: ...How to use electronic circuit diagram 105 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...
Page 106: ...18 1 REMOTE CONTROL 106 CS XE9CKE CU XE9CKE CS XE12CKE CU XE12CKE...