Panasonic CS-WU12VKY Series Operating Instructions Manual Download Page 6

6

Prevent water leakage by ensuring drainage 
pipe is:

 -Connected properly,
 -Kept clear of gutters and containers, or
 -Not immersed in water

After a long period of use or use with any 
combustible equipment, aerate the room 
regularly.
After a long period of use, make sure the 
installation rack does not deteriorate to 
prevent the unit from falling down.

Remote control

Do not use rechargeable (Ni-Cd) batteries. It 
may damage the remote control.

To prevent malfunction or damage of the 
remote control:
• Remove the batteries if the unit is not going 

to be used for a long period of time.

• New batteries of the same type must be 

inserted following the polarity stated.

Power supply

Do not disconnect the plug by pulling the cord 
to prevent electric shock.

Precaution for using R32 refrigerant

The basic installation work procedures are the same as 
conventional refrigerant (R410A, R22) models.

1. Installation (Space)

• Must ensure the installation of pipe-work 

shall be kept to a minimum. Avoid use 
dented pipe and do not allow acute bending.

• Must ensure that pipe-work shall be 

protected from physical damage.

• Must comply with national gas regulations, 

state municipal rules and legislation. Notify 
relevant authorities in accordance with all 
applicable regulations.

• Must ensure mechanical connections be 

accessible for maintenance purposes.

• In cases that require mechanical ventilation, 

ventilation openings shall be kept clear of 
obstruction.

• When disposal of the product, do follow 

to the precautions in #12 and comply with 
national regulations.
Always contact to local municipal offi ces for 
proper handling.

Safety precautions

2. Servicing
2-1. Service personnel

• Any qualifi ed person who is involved with 

working on or breaking into a refrigerant 

circuit should hold a current valid certifi cate 

from an industry-accredited assessment 

authority, which authorizes their competence 

to handle refrigerants safely in accordance 

with an industry recognised assessment 

specifi cation.

• Servicing shall only be performed 

as recommended by the equipment 

manufacturer.

Maintenance and repair requiring the 

assistance of other skilled personnel shall 

be carried out under the supervision of the 

person competent in the use of fl ammable 

refrigerants.

• Servicing shall be performed only as 

recommended by the manufacturer.

2-2. Work

• Prior to beginning work on systems 

containing fl ammable refrigerants, safety 

checks are necessary to ensure that the risk 

of ignition is minimised.

For repair to the refrigerating system, the 

precautions in #2-2 to #2-8 must be followed 

before conducting work on the system.

• Work shall be undertaken under a controlled 

procedure so as to minimize the risk of a 

fl ammable gas or vapour being present while 

the work is being performed.

• All maintenance staff and others working 

in the local area shall be instructed and 

supervised on the nature of work being 

carried out.

• Avoid working in confi ned spaces.

• Wear appropriate protective equipment, 

including respiratory protection, as 

conditions warrant.

• Ensure that the conditions within the area 

have been made safe by limit of use of any 

fl ammable material. Keep all sources of 

ignition and hot metal surfaces away.

2-3. Checking for presence of refrigerant

• The area shall be checked with an 

appropriate refrigerant detector prior to and 

during work, to ensure the technician is 

aware of potentially fl ammable atmospheres.

• Ensure that the leak detection equipment 

being used is suitable for use with fl ammable 

refrigerants, i.e. non sparking, adequately 

sealed or intrinsically safe.

• In case of leakage/spillage happened, 

immediately ventilate area and stay upwind 

and away from spill/release.

• In case of leakage/spillage happened, do 

notify persons down wind of the leaking/spill, 

isolate immediate hazard area and keep 

unauthorized personnel out.

C

M

Y

CM

MY

CY

CMY

K

ACXF55-2303̲OL.ai   6   11/14/2018   10:08:24 AM

ACXF55-2303̲OL.ai   6   11/14/2018   10:08:24 AM

Summary of Contents for CS-WU12VKY Series

Page 1: ... Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference C SLEEP SLEEP POWERFUL POWERFUL nanoe G nanoe G PURIFIER PURIFIER C M Y CM MY CY CMY K ACXF55 2303 OL ai 1 11 14 2018 10 08 09 AM ACXF55 2303 OL ai 1 11 14 2018 10 08 09 AM ...

Page 2: ...C M Y CM MY CY CMY K ACXF55 2303 OL ai 2 11 14 2018 10 08 22 AM ACXF55 2303 OL ai 2 11 14 2018 10 08 22 AM ...

Page 3: ...m from the remote control receiver of the indoor unit FAN DRY Safety precautions 4 9 How to use 10 11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 To confirm Press SET or CLOCK again Please note that the OFF indication is as follows POWER FAN nanoe G CHECK CHECK C M Y CM MY CY CMY K ACXF55 2303 OL ai 3 11 14 2018 10 08 23 AM ACXF55 2303 OL ai 3 11 14 2018 10 08 23 A...

Page 4: ...e that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handing will cause leakage electric shock or fire Confirm with authorised dealer or spe...

Page 5: ...ls Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut on the outdoor...

Page 6: ...eir competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall be performed o...

Page 7: ...ce which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall include but ...

Page 8: ...n When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazing The refriger...

Page 9: ...gerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recover...

Page 10: ... OFF ON the hidden temperature display Hidden display is ON by default when unit is switched on When the display is turn OFF by remote controller It will turn ON automatically for few seconds upon receiving any command from remote or in case of mains power reset To select operation mode AUTO For your convenience COOL To enjoy cool air DRY To dehumidify the environment Unit run with optimised setti...

Page 11: ... before the actual set time in order to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Quick guide TIMER 50 30 This operation is to achieve faster cooling This operation stops automatically after 1 hours If AUTO air swing is set the louver swings up down automatically nanoe G start...

Page 12: ...ning has to be carried out at regular intervals A dirty unit may cause malfunction Please consult authorised dealer Switch off the power supply and unplug before cleaning Do not touch the aluminium fin sharp parts may cause injury Do not use benzine thinner or scouring powder Use only soap pH 7 or neutral household detergent Do not use water hotter than 40 C Indoor unit Wipe the unit gently with a...

Page 13: ...not functioning properly The unit stops and the TIMER indicator blinks Use remote control to retrieve error code Press for 5 seconds Press for 5 seconds to quit checking Press until you hear 4 beep sound then write down the error code Turn the unit off and reveal the error code to authorised dealer 2 1 3 4 operation but if problem persist please consult authorised dealer with error code For certai...

Page 14: ...ep c After hearing a beep sound from the Indoor Unit immediately release the Auto OFF ON button on Indoor Unit All this should be done within 5 seconds Turn on the main power supply to unit Testing Guidelines Cooling Test Mode for Full Load 100 and Half Load 50 1 Mode Select COOL 2 Temperature a 16 ºC for Full Load 100 3 Air Swing S 4 Fan speed et vane position to 3rd step from top b 17 ºC for Hal...

Page 15: ...nasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental breakage Provid...

Page 16: ...urce there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions C M Y CM MY CY CMY K ACXF55 2303 OL ai 16 11...

Reviews: