8.8. OUTDOOR FAN CONTROL
∙
Outdoor fan motor is controlled with 2 speeds. Fan is in operation when the compressor starts operation and stops 30 seconds
after compressor stops operation.
(During 80 seconds, Fan speed is at low).
Fan Speed
Compressor Operating Frequency
Cooling-Soft Dry
Heating
High
Over 45Hz
Over 73Hz
Low
Below 45Hz
Below 73Hz
8.9. AIRFLOW DIRECTION
∙
Blade angle setting (Upper limit reference)
Operation
Blade angle
1
2
3
4
5
heating
Airflow direction auto
Indoor heat exchanger
temperature
A
14°
B
61°
C
0°
Airflow direction manual
-
-
0°
18°
29.4°
45.1°
61°
Cooling
Airflow direction auto
-
0° - 37°
Anti-dew formation control
3° - 37°
Airflow direction manual
-
0°
8°
18°
28°
37°
Anti-dew formation control
3°
11.5°
20°
28.5°
37°
Dry
Airflow direction auto
-
0° - 37°
Anti-dew formation control
3° - 37°
Airflow direction manual
-
0°
8°
18°
28°
37°
Anti-dew formation control
3°
11.5°
20°
28.5°
37°
Stop
138°
∙
Sitting angle
1. Airflow Direction Manual
By pressing the remote control airflow direction setting switch, the blade will move to the indicated angle (1, 2, 3, 4, 5) as shown
in the table. When the remote control OFF/ON switch is pressed, the blade will move to the Close position.
2. Airflow Direction Auto
By setting the airflow direction to AUTO, the blade swings up and down from 0°-37° during Cooling and Soft Dry operation.
During Heating operation, the blade angle will shift according to the indoor heat exchanger temperature as shown below:
27
CS-VG120KE / CU-VG120KE
Summary of Contents for CS-VG120KE
Page 3: ...2 Functions 2 1 REMOTE CONTROL 3 CS VG120KE CU VG120KE ...
Page 4: ...2 2 INDOOR UNIT 4 CS VG120KE CU VG120KE ...
Page 5: ...5 CS VG120KE CU VG120KE ...
Page 6: ...2 3 OUTDOOR UNIT 6 CS VG120KE CU VG120KE ...
Page 9: ...4 Dimensions 4 1 CS VG120KE INDOOR UNIT 9 CS VG120KE CU VG120KE ...
Page 10: ...4 2 CU VG120KE OUTDOOR UNIT 10 CS VG120KE CU VG120KE ...
Page 12: ...6 Block Diagram CS VG120KE CU VG120KE 12 ...
Page 49: ...11 3 INDOOR OUTDOOR UNIT INSTALLATION DIAGRAM 49 CS VG120KE CU VG120KE ...
Page 62: ...13 Technical Data 13 1 OPERATION CHARACTERISTICS 62 CS VG120KE CU VG120KE ...
Page 68: ...CS VG120KE CU VG120KE 68 ...
Page 69: ...15 Printed Circuit Board 15 1 CS VG120KE INDOOR UNIT 69 CS VG120KE CU VG120KE ...
Page 70: ...70 CS VG120KE CU VG120KE ...
Page 71: ...15 2 CU VG120KE OUTDOOR UNIT POWER SUPPLY 71 CS VG120KE CU VG120KE ...
Page 72: ...MAIN INDICATOR 72 CS VG120KE CU VG120KE ...
Page 75: ...16 2 CU VG120KE 16 2 1 Exploded View 75 CS VG120KE CU VG120KE ...
Page 78: ...MEMO ...
Page 79: ...MEMO ...
Page 80: ...Printed in Japan MS1299SO ...