![Panasonic CS-UE18RKE Operating Instructions Manual Download Page 7](http://html.mh-extra.com/html/panasonic/cs-ue18rke/cs-ue18rke_operating-instructions-manual_1508123007.webp)
7
English
To set the timer
2 sets of ON and OFF timers are available
to turn ON or OFF the unit at different preset
times.
2
1
3
1
Select ON or OFF
timer
Example:
OFF at 22:00
• Each time pressed:
Cancel
2
Set the time
3
Con
fi
rm
TIMER
• To cancel ON or OFF timer, press
or
to select respective or then press
.
• If timer is cancelled manually or due to power
failure, you can restore the timer again by
pressing
or
to select respective or
then press
.
• The nearest timer setting will be displayed and
will activate in sequence.
• When ON Timer is set, the unit may start
earlier (up to 35 minutes) before the actual
set time in order to achieve the desired
temperature on time.
• Timer operation is based on the clock set in
the remote control and repeats daily once set.
For clock setting, please refer to Quick guide.
How to use
To adjust air
fl
ow direction
(Remote control display)
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver
swings left/right and up/down automatically.
• In HEAT mode, if AUTO is set, the horizontal
louver is
fi
xed at the predetermined position.
The vertical louver swings left/right after the
temperature rises.
• Do not adjust the louver by hand.
Operation conditions
Use this air conditioner under the following temperature range.
Temperature (°C)
Indoor
Outdoor
DBT
WBT
DBT
WBT
COOL
Max. 32
23
43
26
Min. 16
11
5
-
HEAT
Max. 30
-
24
18
Min. 16
-
-10
-11
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Auto Restart Control
• If power is resumed after a power failure, the
operation will restart automatically after a period
of time with previous operation mode and air
fl
ow
direction.
• This control is not applicable when TIMER is set.