background image

5

Safety Precautions

CAUTION

Indoor unit and outdoor unit

Do not wash the indoor unit with water, 

benzine, thinner or scouring powder to avoid 

damage or corrosion at the unit.
Do not use for preservation of precise 

equipment, food, animals, plants, artwork 

or other objects. This may cause quality 

deterioration, etc.
Do not use any combustible equipment in front 

of the air

fl

 ow outlet to avoid 

fi

 re propagation.

Do not expose plants or pet directly to air

fl

 ow to 

avoid injury, etc.

Do not touch the sharp aluminium 

fi

 n, 

sharp parts may cause injury.

Do not switch ON the indoor unit when waxing 

the 

fl

 oor. After waxing, aerate the room properly 

before operating the unit.
Do not install the unit in oily and smoky areas 

to prevent damage to the unit.
Do not dismantle the unit for cleaning purpose 

to avoid injury.
Do not step onto an unstable bench when 

cleaning the unit to avoid injury.
Do not place a vase or water container on the 

unit. Water may enter the unit and degrade the 

insulation. This may cause an electric shock.
Do not open window or door for long time during 

operation, it may lead to inef

fi

 cient power usage 

and uncomfortable temperature changes.
Prevent water leakage by ensuring drainage pipe is:

- Connected properly,

- Kept clear of gutters and containers, or

- Not immersed in water
After a long period of use or use with any 

combustible equipment, aerate the room regularly.
After a long period of use, make sure the 

installation rack does not deteriorate to prevent 

the unit from falling down.

Remote control

Do not use rechargeable (Ni-Cd) batteries. It 

may damage the remote control.

To prevent malfunction or damage of the 

remote control:

• Remove the batteries if the unit is not going to 

be used for a long period of time.

• New batteries of the same type must be 

inserted following the polarity stated.

Power supply

Do not disconnect the plug by pulling the cord 

to prevent electric shock.

nanoe™-G generator

Do not touch the sharp pin which may cause 

injury.

If the supply cord is damaged, it must be 

replaced by the manufacturer, service agent 

or similarly quali

fi

 ed persons in order to avoid 

a hazard.
It is strongly recommended to be installed 

with Earth Leakage Circuit Breaker (ELCB) 

or Residual Current Device (RCD) to prevent 

electric shock or 

fi

 re.

To prevent overheating, 

fi

 re or electric shock:

• Insert the power plug properly.

• Dust on the power plug should be periodically 

wiped with a dry cloth.

Stop using the product if any abnormality/

failure occurs and disconnect the power plug or 

turn off the power switch and breaker.

(Risk of smoke/

fi

 re/electric shock) 

Examples of abnormality/failure

• The ELCB trips frequently.

• Burning smell is observed.

• Abnormal noise or vibration of the unit is 

observed.

• Water leaks from the indoor unit.

• Power cord or plug becomes abnormally hot.

• Fan speed cannot be controlled.

• The unit stops running immediately even if it 

is switched on for operation.

• The fan does not stop even if the operation 

is stopped.

Contact your local dealer immediately for 

maintenance/repair.
Replacement or installation of power plugs 

shall be performed by authorised/quali

fi

 ed 

personnel only. The wires in this mains lead are 

coloured in accordance with the following code:

Terminals

Red

wires

live

neutral

earth

colours (GB Standard)

blue

green-yellow

brown

Black

Green/Yellow

Wiring colour may vary depending on a country

wiring code’s standard.

This equipment must be earthed to prevent 

electrical shock or 

fi

 re.

Prevent electric shock by switching off the 

power supply and unplug:

- Before cleaning or servicing,

- When extended non-use, or

- During abnormally strong lightning activity.

English

Summary of Contents for CS-U9XKD-3

Page 1: ...s thoroughly and keep them for future reference Before installation the installer should Read the Installation Instructions then request the customer keep them for future reference Remove the remote c...

Page 2: ...ol receiver on the indoor unit Quick Guide Inserting the batteries 1 2 3 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries 3 Close the cover A Clock setting 1 Press CLOCK then...

Page 3: ...seconds to show the temperature as C or F 2 Press to select the desired mode DRY iAUTO X COOL Table of Contents Safety Precautions 4 11 How to Use 12 14 To Learn More 15 Cleaning the Air Conditioner 1...

Page 4: ...nstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant t...

Page 5: ...for a long period of time New batteries of the same type must be inserted following the polarity stated Power supply Do not disconnect the plug by pulling the cord to prevent electric shock nanoe G ge...

Page 6: ...l the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of...

Page 7: ...he precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised a...

Page 8: ...ernally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the...

Page 9: ...the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also t...

Page 10: ...minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging...

Page 11: ...employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refri...

Page 12: ...ave a low noise operation When iAUTO X mode is selected the fan speed is automatically set to AUTO To adjust the fan speed cancel iAUTO X mode QUIET This operation reduces airflow noise To enjoy fresh...

Page 13: ...2 C 4 F from the set temperature to accelerate the room cooling effect Fan speed is set to AUTO and you cannot change the fan speed After a maximum of 4 hours the unit returns to the last set tempera...

Page 14: ...n Press or to select the respective setting or then press The nearest timer setting is displayed and will activate in sequence The timer operation follows the clock setting on the remote control and w...

Page 15: ...ailure the operation will restart automatically with the last operation mode and airflow direction This control is not applicable when TIMER is set nanoe X filter deactivation Depending on the unit s...

Page 16: ...ration Air filters Once every 2 weeks Wash rinse the filters gently with water to avoid damaging the surface Dry the filters thoroughly under a shade away from fire or direct sunlight Replace any dama...

Page 17: ...ials used in plastic parts It is accelerated when exposed to heat sun light UV light or environmental factors After extended use dust may cover the front panel grilles and the wall surrounding the uni...

Page 18: ...refer The remote control is missing or a malfunction has occurred above After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents C...

Page 19: ...r abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mis...

Page 20: ...attery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved WA...

Reviews: