Panasonic CS- U12WKY Series Operating Instructions Manual Download Page 6

POWERFUL, SLEEP, TIMER etc.
function will not resume after power failure.

If AUTO is set, the louver swings up/down 
automatically.

52            30

TIMER

OFF

ON

CANCEL

• To cancel ON or OFF timer, press        . 
• If timer is cancelled manually or due to power 

failure, you can restore the timer again by 
pressing         or        then wait for “5” sec. 

• The nearest timer setting will be displayed and 

will activate in sequence.

• When ON Timer is set, the unit may start 

earlier (up to “15” minutes) before the actual 
set time in order to achieve the desired 
temperature on time.

ON

OFF

CANCEL

11

Select ON or OFF
timer

Set the time

Confirm

Example:
OFF at 14:00  

Press the OFF 
button.  

OFF

OFF

OFF

OFF

OFF

OFF

• 

Wait for “5” second to set timer.  

• 

Press OFF button again to
increase timer time in step
of “10” minutes.  

• 

Press the button to turn on.

10

AUTO - For your convenience 

COOL - To enjoy cool air 

DRY - To dehumidify the environment

Unit run with optimised settings.
You can change the temperature according to 
your comfort. 

To reduce power consumption during COOL mode, 
use curtains to screen off sunlight and outdoor heat.

Unit operates at auto fan speed to give a gentle
cooling operation.

FAN - To operate Air-Con in “Fan Only” mode

* Indoor unit temp. display will show set temp. for 
  AUTO,COOL & DRY mode and room temp. for FAN 
  mode.

Only indoor unit fan operates as per remote settings.
Outdoor is OFF, so no cooling acheived.
Provides air circulation in the room.

“SL” will be displayed on Remote

The unit is turned off after “8” hours. 

This operation provides you with a comfortable
environment while sleeping by gradually increase
the set temperature 1 °C after “3” hours operation.

This operation is to achieve faster cooling.

POWERFUL

The unit displays set
temperature.

Press to turn ON/OFF
the hidden display.

 ( 6 / 8 )

A C I 2 P R 0 9 2 0 1 

SLEEP

POWER

POWERFUL

TIMER

‘CL’ will be displayed on the remote controller.
While ‘CL’ is diplayed, all other functions of the
remote controller will be disabled, except for
ON/OFF button.
Press CLEAN button again to cancel.

CLEAN

To clean dust on evap. coil of
the Air-Conditioner Unit

Press‘LOCK’ for 5 seconds to lock/unlock
remote keypad.
When keypad is lock, remote display show Lo

LOCK

when any button is pressed. 

This operation stops automatically after 1 hour.

Summary of Contents for CS- U12WKY Series

Page 1: ...this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information include...

Page 2: ...g instructions 12 Troubleshooting 13 BEE Regulation 1 4 Information 15 2 8 FAN DRY Operating the unit at 24 C or higher degrees may save energy Better comfort condition at 24 C or higher degrees A C I 2 P R 0 9 2 0 1 PM 2 5 Filter Ag Clean Filter 8m ...

Page 3: ... parts may cause injury Do not switch ON the indoor unit when waxing the floor After waxing aerate the room properly before operating the unit Do not install the unit in oily and smoky areas to prevent damage to the unit Do not dismantle the unit for cleaning purpose to avoid injury Do not step onto an unstable bench when cleaning the unit to avoid injury Do not place a vase or water container on t...

Page 4: ...mage to cables excessive number of connections terminals not made to original specification damage to seals incorrect fitting of glands etc Ensure that apparatus is mounted securely Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres Replacement parts shall be in accordance with the manufacturer s speci...

Page 5: ...nductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere The test apparatus shall be at the correct rating Replace components only with parts specified by the manufacturer Unsp...

Page 6: ...use curtains to screen off sunlight and outdoor heat Unit operates at auto fan speed to give a gentle cooling operation FAN To operate Air Con in Fan Only mode Indoor unit temp display will show set temp for AUTO COOL DRY mode and room temp for FAN mode Only indoor unit fan operates as per remote settings Outdoor is OFF so no cooling acheived Provides air circulation in the room SL will be displaye...

Page 7: ...the dust filters thoroughly under shade away from fire or direct sunlight Replace any damaged filters Ag Clean Filter PM 2 5 filter Clean the filter whenever necessary Don t wash rinse the filter with water The surface of the filter shouldn t be rubbed with any object The filter shouldn t be pulled with strong force as it may get damaged 12 7 8 A C I 2 P R 0 9 2 0 1 Front Panel Dust Filters Ag Clean filter...

Page 8: ... number http www panasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its acciden...

Reviews: