8
Cleaning the Air Conditioner
Cleaning has to be carried out at regular intervals to ensure the unit is at optimal
performance. A dirty unit may cause malfunction and you may retrieve “H 99” error
code. Consult an authorised dealer.
• Before cleaning, switch off the power supply and unplug the unit.
• Do not touch the aluminium
fi
n as the sharp parts may cause injury.
• Do not use benzine, thinner or scouring powder.
• Use soap ( pH 7) or neutral household detergent only.
• Do not use water hotter than 40 °C / 104 °F.
Air
fi
lters
Once every 2 weeks
• Wash/rinse the
fi
lters gently with water to avoid damaging the surface.
• Dry the
fi
lters thoroughly under a shade, away from
fi
re or direct sunlight.
• Replace any damaged
fi
lters.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Indoor
Single split outdoor unit
*
1
Multi split outdoor unit
*
2
DBT
WBT
DBT
WBT
DBT
WBT
COOL
Max.
32 (89.6)
23 (73.4)
43 (109.4)
26 (78.8)
46 (114.8)
26 (78.8)
Min.
16 (60.8)
11 (51.8)
-10 (14.0)
-
-10 (14.0)
-
HEAT
Max.
30 (86.0)
-
24 (75.2)
18 (64.4)
24 (75.2)
18 (64.4)
Min.
16 (60.8)
-
-15 (5.0)
-16 (3.2)
-15 (5.0)
-16 (3.2)
DBT: Dry bulb temperature, WBT: Wet bulb temperature
*
1
CU-TZ60ZKE, CU-TZ71ZKE
*
2
CU-3Z68TBE, CU-4Z68TBE, CU-4Z80TBE, CU-5Z90TBE
Summary of Contents for CS-TZ60ZKEW
Page 35: ...35 DE Memo Informationen...
Page 62: ...62 8...
Page 63: ...63 EL ELCB Earth Leakage Circuit Breaker RCD Residual Current Device ELCB...
Page 64: ...64 Ni Cd R32 Amin m Amin m R32...
Page 65: ...65 EL 15 cm Panasonic Comfort Cloud Panasonic Cloud WIFI...
Page 67: ...67 EL Pb ON OFF nanoe X...
Page 70: ...70 8...
Page 71: ...71 BG ELCB RCD ELCB...
Page 72: ...72 Ni Cd R32 A A A R32...
Page 73: ...73 BG 15 Panasonic Comfort Cloud Panasonic Cloud WIFI...
Page 75: ...75 BG Pb nanoe X...
Page 79: ...Memo...