101
Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below
and the positions of the vane are as Figure 2 above.
Pattern
1 2 3 4 5
Airflow Direction
Patterns at Remote
Control
Vane Angle (°)
90
65
77.5
102.5
115
* The vertical vane angle tolerance is /- 5 degree.
14.5 Timer Control
There are 2 sets of ON and OFF timer available to turn the unit ON or OFF at different preset time.
If more than one timer had been set, the upcoming timer will be displayed and will activate in sequence.
14.5.1 ON
Timer
Control
ON timer 1 and ON timer 2 can be set using remote control, the unit with timer set will start operate earlier than
the setting time.
This is to provide a comfortable environment when reaching the set ON time.
60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to
determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting
time.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
14.5.2 OFF Timer Control
OFF timer 1 and OFF timer 2 can be set using remote control, the unit with timer set will stop operate at set time.
Indoor Heat Exchanger
Temperature
A: swing
B: fix front
Figure 1
Figure 2
43°C
40°C
0°
1
3
2
Top View
4
5
Indoor intake air
temperature (
o
C)
Outdoor air
temperature (
o
C)
30
30
35
Cooling/Soft Dry
(
o
C)
10 min
15 min
5 min
25
Indoor intake air
temperature (
o
C)
Outdoor air
temperature (
o
C)
15
0
5
Heating
(
o
C)
30 min
25 min
35 min
5