Indoor Unit
Auto Mode Operation Selection Button
When the remote control cannot be used or
for repairing and testing ,please use this
button.
Power Switch ON/OFF
Signal Receiving Sound Control
Keep pressing this button for 10sec to turn
on or turn off the signal receiving sound.
Operation Indication Lamps
Operation (green)
Timer(orange)
Iights up in operation
Blinks during Test
Run operation and
determining Auto
Operation mode
Timer in operation
Operation Mode
Heating/Cooling/Soft Dry/Auto Operation
Time Delay Safety Control
The unit will restart operation after 3-4
minutes after each pause.
7-Minutes Time Save Control
7-minutes automatic restarting at Cooling
Operation
Anti-freezing Control for the Evaporator
Cooling or Soft Dry Operation
Warm Booting Control(Heating Mode)
Indoor fan starts running when temperature
of evaporator reaches 30
or above.
When temperature of evaporator is between
30
and 40
,indoor fan will run at Super Low
or Low speed.
When temperature of evaporator reaches 34
,
Warm Booting Operation ends.
C
C
C
C
High,Med,Low,Auto
Auto Fan Speed
Indoor Fan Speed Controll
Vertical airflow direction controlled by
remote control.
Horizontal airflow direction can be
adjusted manually.
Airflow Direction Control
Delayed On-timer Control
For cooling or soft dry mode, the unit
starts 15 minutes before the set time with
the remote control, but for heating mode
30 minutes before the set time.
Filter Reset Button
When the total operation time reaches 360 hours
the light will light up. After cleaning the air filter
and reinstalling it ,press this button to reset.
Auto Restart Control
If the operation is stopped due to a power
failure, the operation will be automatically
restarted when the power is resumed, timer
setting will be cancelled.
3
CS-SA18CKP / CU-SA18CKP5
Summary of Contents for CS-SA18CKP
Page 7: ...3 Dimensions 7 CS SA18CKP CU SA18CKP5 ...
Page 8: ...8 CS SA18CKP CU SA18CKP5 ...
Page 9: ...4 Refrigeration Cycle Diagram 9 CS SA18CKP CU SA18CKP5 ...
Page 10: ...5 Block Diagram 10 CS SA18CKP CU SA18CKP5 ...
Page 11: ...6 Wiring Diagram 11 CS SA18CKP CU SA18CKP5 ...
Page 15: ...Time Graph for soft dry operation 15 CS SA18CKP CU SA18CKP5 ...
Page 23: ...23 CS SA18CKP CU SA18CKP5 ...
Page 50: ...12 Technical Data Thermostat characteristics CS SA18CKP CU SA18CKP5 50 CS SA18CKP CU SA18CKP5 ...
Page 51: ... Operating characteristics CS SA18CKPCU SA18CKP5 51 CS SA18CKP CU SA18CKP5 ...
Page 52: ...13 Exploded View CS SA18CKP 52 CS SA18CKP CU SA18CKP5 ...
Page 54: ...15 Exploded View CU SA18CKP5 54 CS SA18CKP CU SA18CKP5 ...
Page 57: ...SCHEMATIC DIAGRAM 2 4 CS SA18CKP CU SA18CKP5 6 7 8 9 10 11 57 CS SA18CKP CU SA18CKP5 ...
Page 58: ...SCHEMATIC DIAGRAM 3 4 CS SA18CKP CU SA18CKP5 11 12 13 14 15 16 58 CS SA18CKP CU SA18CKP5 ...