Removal procedure of the cross flow fan
1. Remove the fan motor.
(Refer to the removal procedure of fan motor,
Fig 8
)
Remove the securing screw of the front grille, pull the
front grille down towards you.
2. Loosen the bearing on the left side of the cross flow fan.
3. Take off the securing-tabs to the left of the heat
exchanger.
Pull the heat exchanger forward (left side). (
Fig 10
)
The cross flow fan can be removed. (
Fig 10
)
Fig 8
Fig 9
Fig 10