8.9. Test Running
8.9.1. Connect the power supply
1. Connect the power supply cord to independent power
supply.
•
•
•
•
Circuit breaker is necessary.
2. Prepare the remote controller
•
•
•
•
Insert two batteries
•
•
•
•
Remove the cover from the back of the remote
controller.
Insert two batteries
•
•
•
•
Be sure that the (+) and (-) directions are correct.
•
•
•
•
Be sure that both batteries are new.
•
•
•
•
Re-attach the cover.
•
•
•
•
Slide the cover back into position.
3. Operate the unit at cooling mode operation for 15 minutes
or more.
8.9.2. Evaluation of the performance
1. Operate the air conditioner for 15 minutes.
2. Measure the temperature of the intake and discharge air.
3. Ensure the difference betwan the intake temperature and
the discharge is more than 8°C in cooling operation, or
more than 14°C in heating operation.
39
CS-SA9CKP CU-SA9CKP5 / CS-SA12CKP CU-SA12CKP5
Summary of Contents for CS-SA12CKP
Page 9: ...3 Dimensions 9 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5 ...
Page 10: ...10 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5 ...
Page 11: ...4 Refrigeration Cycle Diagram 11 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5 ...
Page 12: ...5 Block Diagram 12 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5 ...
Page 13: ...6 Wiring Diagram 13 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5 ...
Page 17: ...Time Graph for soft dry operation 17 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5 ...
Page 26: ...26 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5 ...
Page 55: ...13 Exploded View CS SA9CKP CS SA12CKP 55 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5 ...
Page 57: ...15 Exploded View CU SA9CKP5 CU SA12CKP5 57 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5 ...
Page 61: ...17 1 REMOTE CONTROL 61 CS SA9CKP CU SA9CKP5 CS SA12CKP CU SA12CKP5 ...