WARNING

 

19. 

During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration 
piping and valves at opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury 
etc.). 

20. 

During pump down operation, stop the compressor before remove the refrigeration piping. (Removal of refrigeration piping while 
compressor is operating and valves are opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result 
in explosion, injury etc.).. 

21. 

After completion of installation or service, confirm there is no leakage of refrigerant gas. It may generate toxic gas when the refrigerant 
contacts with fire. 

22.  Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when the refrigerant contacts with fire.

 

23.  Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury 

 

24.  Must not use other parts except original parts describe in catalog and manual.

 

25.  Using of refrigerant other than the specified type may cause product damage, burst and injury etc. 

 
 

  

CAUTION

 

1. 

Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of 
the unit, it may cause fire. 

 

2. 

Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the 
furniture. 

3. 

Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may 
break and cause refrigerant gas leakage. 

4. 

Do not touch outdoor unit air inlet and aluminium fin. It may cause injury. 

 

5. 

Select an installation location which is easy for maintenance. 

6. 

Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use 
a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). 
Pb free solder will tend to splash when heated too high (about 1100°F / 600°C). 

7. 

Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the 
following methods. 
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some 
countries, permanent connection of this room air conditioner to the power supply is prohibited. 
i.  Power supply connection to the receptacle using a power plug.  
    Use an approved 15/16A (1.0 ~ 1.75HP) or 16A (2.0HP) or 20A (2.5HP), power plug with earth pin for the connection to the socket. 
ii. Power supply connection to a circuit breaker for the permanent connection. 
    Use an approved 16A (1.0 ~ 2.0HP) or 20A (2.5HP), circuit breaker for the permanent connection. It must be a double pole switch with 
    a minimum 3.0 mm contact gap. 

8. 

Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. Take 
care of the liquid refrigerant, it may cause frostbite. 

 

9. 

Installation or servicing work: It may need two people to carry out the installation or servicing work.

 

10.  Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc. 

 

11.  Do not sit or step on the unit, you may fall down accidentally. 

 

12.  Do not touch the sharp aluminum fins , sharp parts may cause injury. 

 

Summary of Contents for CS-S9NKUW-1

Page 1: ...bite be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit WARNING This service information is designed for experienced repair technicians only and is not de...

Page 2: ...f Dry Mode 49 11 7 Powerful Mode Operation 50 11 8 Timer Control 50 11 9 Random Auto Restart Control 50 11 10 Indication Panel 51 12 Protection Control 52 12 1 Restart Control Time Delay Safety Contro...

Page 3: ...alled with Earth Leakage Circuit Breaker ELCB or Residual Current Device RCD Otherwise it may cause electrical shock and fire in case equipment breakdown or insulation breakdown 10 Do not use joint ca...

Page 4: ...cause refrigerant gas leakage 4 Do not touch outdoor unit air inlet and aluminium fin It may cause injury 5 Select an installation location which is easy for maintenance 6 Pb free solder has a higher...

Page 5: ...rent A Max Input Power W 4 1 900 5 4 1 22k Starting Current A 3 7 5 1 Min Circuit Ampacity 15 0 15 0 Max Overcurrent Protection 15 0 15 0 Type Hermetic Motor Rotary Hermetic Motor Rotary Motor Type Br...

Page 6: ...16 7 5 8 16 7 5 8 Drain Hose Length mm inch 650 25 5 8 650 25 5 8 Fin Material Aluminium Pre Coat Aluminium Pre Coat Fin Type Slit Fin Slit Fin Row x Stage x FPI 2 x 15 x 19 2 x 15 x 21 Indoor Heat E...

Page 7: ...Input Power W 9 0 1 99k 10 8 2 48k Starting Current A 8 3 11 2 Min Circuit Ampacity 15 0 20 0 Max Overcurrent Protection 20 0 25 0 Type Hermetic Motor Scroll Hermetic Motor Scroll Motor Type Brushless...

Page 8: ...nch 16 7 5 8 16 7 5 8 Drain Hose Length mm inch 650 25 5 8 650 25 5 8 Fin Material Aluminium Pre Coat Aluminium Pre Coat Fin Type Slit Fin Slit Fin Row x Stage x FPI 2 x 15 x 21 2 x 15 x 21 Indoor Hea...

Page 9: ...9 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...

Page 10: ...10 4 Dimensions 4 1 Indoor Unit 4 1 1 CS S9NKUW 1 CS S12NKUW 1...

Page 11: ...11 4 1 2 CS S18NKU 1 CS S22NKU 1...

Page 12: ...12 4 2 Outdoor Unit 4 2 1 CU S9NKU 1 CU S12NKU 1 4 2 2 CU S18NKU 1 CU S22NKU 1...

Page 13: ...13 5 Refrigeration Cycle Diagram 5 1 CS S9NKUW 1 CU S9NKU 1 CS S12NKUW 1 CU S12NKU 1...

Page 14: ...14 5 2 CS S18NKU 1 CU S18NKU 1 CS S22NKU 1 CU S22NKU 1...

Page 15: ...15 6 Block Diagram 6 1 CS S9NKUW 1 CU S9NKU 1 CS S12NKUW 1 CU S12NKU 1...

Page 16: ...16 6 2 CS S18NKU 1 CU S18NKU 1 CS S22NKU 1 CU S22NKU 1...

Page 17: ...17 7 Wiring Connection Diagram 7 1 Indoor Unit 7 1 1 CS S9NKUW 1 CS S12NKUW 1...

Page 18: ...18 7 1 2 CS S18NKU 1 CS S22NKU 1...

Page 19: ...19 7 2 Outdoor Unit 7 2 1 CU S9NKU 1 CU S12NKU 1...

Page 20: ...20 7 2 2 CU S18NKU 1...

Page 21: ...21 7 2 3 CU S22NKU 1...

Page 22: ...22 8 Electronic Circuit Diagram 8 1 Indoor Unit 8 1 1 CS S9NKUW 1 CS S12NKUW 1...

Page 23: ...23 8 1 2 CS S18NKU 1 CS S22NKU 1...

Page 24: ...24 8 2 Outdoor Unit 8 2 1 CU S9NKU 1 CU S12NKU 1...

Page 25: ...25 8 2 2 CU S18NKU 1...

Page 26: ...26 8 2 3 CU S22NKU 1...

Page 27: ...27 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board...

Page 28: ...28 9 1 2 Power Printed Circuit Board 9 1 3 Indicator Printed Circuit Board...

Page 29: ...29 9 2 Outdoor Unit 9 2 1 Main Printed Circuit Board 9 2 1 1 CU S9NKU 1 CU S12NKU 1...

Page 30: ...30 9 2 1 2 CU S18NKU 1 CU S22NKU 1...

Reviews: