51
11.4.2 Horizontal
Airflow
•
Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the
angles as stated below.
Operation Mode
Vane angle (°)
Cooling and Soft dry
68 ~ 112
•
Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below
and the positions of the vane are as Figure 2 above:
Pattern 1 2 3 4 5
Airflow Direction
Patterns at Remote
Control
Vane Angle (°)
90
68
78
102
112
11.5 Quiet Operation (Cooling Mode/Cooling Area of Dry Mode)
•
Purpose
o
To provide quiet cooling operation compare to normal operation.
•
Control
condition
o
Quiet operation start condition
When “QUIET” button at remote control is pressed twice.
QUIET/ECONOMY LED illuminates (low intensity).
o
Quiet operation stop condition
When one of the following conditions is satisfied, quiet operation stops:
•
QUIET button is pressed again.
•
Stop by OFF/ON switch.
•
Timer “off” activates.
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
During quiet operation, if timer “on” activates, quiet operation maintains.
After off, when on back, quiet operation is not memorised.
•
Control
contents
o
Fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi, Me, Lo for 3dB (some models more than 3dB).
o
Fan speed for quiet operation is reduced from setting fan speed.
o
Outdoor fan speed is change to QLo (S24NKR & S28NKR).
o
Compressor frequency reduced.
Summary of Contents for CS-S9NKR
Page 11: ...11 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...
Page 12: ...12 4 Dimensions 4 1 Indoor Unit 4 1 1 CS S9NKR CS S12NKR...
Page 13: ...13 4 1 2 CS S18NKR CS S24NKR CS S28NKR...
Page 14: ...14 4 2 Outdoor Unit 4 2 1 CU S9NKR CU S12NKR 4 2 2 CU S18NKR CU S24NKR CU S28NKR...
Page 15: ...15 5 Refrigeration Cycle Diagram 5 1 CS S9NKR CU S9NKR CS S12NKR CU S12NKR...
Page 16: ...16 5 2 CS S18NKR CU S18NKR CS S24NKR CU S24NKR CS S28NKR CU S28NKR...
Page 17: ...17 6 Block Diagram 6 1 CS S9NKR CU S9NKR CS S12NKR CU S12NKR...
Page 18: ...18 6 2 CS S18NKR CU S18NKR...
Page 19: ...19 6 3 CS S24NKR CU S24NKR...
Page 20: ...20 6 4 CS S28NKR CU S28NKR...
Page 21: ...21 7 Wiring Connection Diagram 7 1 Indoor Unit 7 1 1 CS S9NKR CS S12NKR...
Page 22: ...22 7 1 2 CS S18NKR CS S24NKR CS S28NKR...
Page 25: ...25 7 2 3 CU S24NKR...
Page 26: ...26 7 2 4 CU S28NKR...
Page 27: ...27 8 Electronic Circuit Diagram 8 1 Indoor Unit 8 1 1 CS S9NKR CS S12NKR...
Page 28: ...28 8 1 2 CS S18NKR CS S24NKR CS S28NKR...
Page 29: ...29 8 2 Outdoor Unit 8 2 1 CU S9NKR CU S12NKR...
Page 30: ...30 8 2 2 CU S18NKR...
Page 31: ...31 8 2 3 CU S24NKR...
Page 32: ...32 8 2 4 CU S28NKR...
Page 34: ...34 9 1 1 2 CS S18NKR CS S24NKR CS S28NKR 9 1 2 Indicator Printed Circuit Board...
Page 35: ...35 9 2 Outdoor Unit 9 2 1 Main Printed Circuit Board 9 2 1 1 CU S9NKR CU S12NKR...
Page 36: ...36 CN DEMAND AC GND CN PWR...
Page 37: ...37 9 2 2 CU S18NKR...
Page 38: ...38 9 2 3 CU S24NKR CU S28NKR...
Page 42: ...42...
Page 90: ...90 Figure 3 Figure 4 15 1 1 3 To remove discharge grille Figure 5...
Page 92: ...92 Figure 9 Figure 10...
Page 96: ...96 Figure 20 Figure 21...
Page 124: ...124 Printed in Malaysia SB0712 0...