Panasonic CS-S12NKUW-1 Operating Instructions Manual Download Page 7

ENGLISH

7

7

TO ENJOY QUIET OPERATION

•  This operation reduces air

fl

 ow noise.

8

TO REACH TEMPERATURE 

QUICKLY

•  Single Split System: This operation stops automatically 

after 20 minutes. 

•  Multi Split System: Press the button again or turn OFF the 

unit to stop this operation.

9

Press and hold for 5 seconds to dim or restore the 

unit’s indicator brightness.

10

Press and hold for approximately 10 seconds to 

show temperature setting in °C or °F.

11

Press and hold for approximately 5 seconds to show 

12-hour (am/pm) or 24-hour time indication.

12

Press to restore the remote control’s default setting.

13

Not used in normal operations.

NOTES

NOTES

QUIET

 , 

POWERFUL

•  Can be activated in all modes and can be cancelled by 

pressing the respective button again.

QUIET

 , 

POWERFUL

•  Cannot be selected at the same time.

TO SET THE TIMER

TO SET THE TIMER

•  To turn ON or OFF the unit at a preset time.

ON

OFF

1

2

SET

Select ON or 

OFF timer

Set the time

Con

fi

 rm

•  To cancel ON or OFF timer, press 

ON

 or 

OFF

 then 

press 

CANCEL

.

•  When ON Timer is set, the unit may start earlier (up 

to 15 minutes) before the actual set time in order to 
achieve the desired temperature on time.

•  Timer operation is based on the clock set in the 

remote control and repeats daily once set. For clock 
setting, please refer to Remote Control Preparation 
on the back cover.

•  If timer is cancelled manually or due to power failure, 

you can restore the previous setting (once power is 
resumed) by pressing 

SET

.

Summary of Contents for CS-S12NKUW-1

Page 1: ...erating Instructions Air Conditioner Model No Indoor Unit Single Split Outdoor Unit Outdoor Unit CS S9NKUW 1 CU S9NKU 1 CS S12NKUW 1 CU S12NKU 1 CS S18NKU 1 CU S18NKU 1 CS S22NKU 1 CU S22NKU 1 Multi Split Outdoor Unit CU 2S18NBU 1 Panasonic Appliances Air Conditioning Malaysia Sdn Bhd 2012 Unauthorized copying and distribution is a violation of law ...

Page 2: ...an actions that is COMPULSORY WARNING WARNING INDOOR UNIT AND OUTDOOR UNIT This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure...

Page 3: ...he remote control Remove the batteries if the unit is not going to be used for a long period of time New batteries of the same type must be inserted following the polarity stated WARNING WARNING REMOTE CONTROL Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries POWER SUPPLY Do not use a modified cord joint cord extensio...

Page 4: ...ps Multi Split System CS S9NKUW 1 CS S9NKUW 1 CU 2S18NBU 1 25 Amps 208 230V CS S9NKUW 1 CS S12NKUW 1 CU 2S18NBU 1 CS S12NKUW 1 CS S12NKUW 1 CU 2S18NBU 1 Living room Living room Multi Split Outdoor Unit Multi Split Outdoor Unit INDOOR UNIT INDOOR UNIT It is possible to operate the indoor units individually or simultaneously The operation mode priority is given to the first unit that turned on Durin...

Page 5: ...il 1 beep is heard then release Cooling Press the button to turn off 8 AIR PURIFYING FILTER Vacuum the air purifying filter It is recommended to clean the filter every 6 months Replace the filter every 3 years or replace any damaged filter Part no CZ SA20P 9 AIR FILTERS Air filter cleaning is required every two weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dr...

Page 6: ...emperature For Multi Split System COOL mode To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode DRY mode To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation 4 TO SELECT FAN SPEED 5 OPTIONS FAN SPEED For AUTO the indoor fan speed is automatically adjusted according to the operation mode 5 TO ...

Page 7: ...ns NOTES NOTES QUIET POWERFUL Can be activated in all modes and can be cancelled by pressing the respective button again QUIET POWERFUL Cannot be selected at the same time TO SET THE TIMER TO SET THE TIMER To turn ON or OFF the unit at a preset time ON OFF 1 2 SET Select ON or OFF timer Set the time Confirm To cancel ON or OFF timer press ON or OFF then press CANCEL When ON Timer is set the unit m...

Page 8: ...icing Check the following before calling for servicing SYMPTOM SYMPTOM CHECK CHECK Cooling operation is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents Noisy during operation Check if the unit has been installed at an incline Close the front panel properly Remote control does ...

Page 9: ...of this product should follow the manufacturer s refrigerant charging and airflow instructions Failure to confirm proper charge and airflow may reduce energy efficiency and shorten equipment life Federal Communications Commission Interference Statement This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interfe...

Page 10: ...MEMO ...

Page 11: ...MEMO ...

Page 12: ...N SPEED MODE QUIET TEMP OFF ON AIR SWING POWERFUL TIMER SET CANCEL ON OFF 1 2 3 SET CHECK CLOCK RESET AC RC 2 1 3 MODE MODE AUTO DRY COOL Select the desired mode 1 OFF ON OFF ON Start stop the operation 2 TEMP TEMP Select the desired temperature 3 Printed in Malaysia F568314 YS1211 1 Remote Control Preparation Remote Control Preparation 1 2 3 TIMER SET CANCEL ON OFF 1 2 3 SET CHECK CLOCK RESET AC ...

Reviews: