Panasonic CS-S12NKUW-1 Operating Instructions Manual Download Page 2

2

Thank you for purchasing

Panasonic Air Conditioner

TABLE OF CONTENTS

TABLE OF CONTENTS

SAFETY PRECAUTIONS

2~3

MULTI AIR CONDITIONER 
SYSTEM

4

INDOOR UNIT

5

REMOTE CONTROL

6~7

TROUBLESHOOTING

8

INFORMATION

9

QUICK GUIDE

BACK COVER

NOTE

NOTE

The illustrations in this manual are for 

explanation purposes only and may 

differ from the actual unit. They are 

subjected to change without notice for 

future improvement.

OPERATION CONDITION

OPERATION CONDITION

Use this air conditioner under the following 

temperature range

Temperature (

˚

F)

Indoor

*DBT *WBT

COOLING

Max.

89.6

73.4

Min.

60.8

51.8

Temperature (

˚

F)

Outdoor

*DBT *WBT

COOLING

Max.

109.4

78.8

Min.

60.8

51.8

* DBT

:  Dry bulb temperature

* WBT

:  Wet bulb temperature 

SAFETY PRECAUTIONS

To prevent personal injury, injury to others, or property damage, please 

comply with the following.

Incorrect operation due to failure to follow instructions below may cause 

harm or damage, the seriousness of which is classi

fi

 ed as below:

  

WARNING

WARNING

This sign warns of death or 
serious injury.

  

CAUTION

CAUTION

 

This sign warns of injury or 
damage to property.

The instructions to be followed are classi

fi

 ed by the following symbols:

This symbol denotes an action 
that is PROHIBITED.

 

 

 

These symbols denote an 
actions that is COMPULSORY.

 

WARNING

WARNING

INDOOR UNIT AND OUTDOOR UNIT

This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, 

or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appliance 

by a person responsible for their safety. Children should be 

supervised to ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to clean the 

internal parts, repair, install, remove and reinstall the unit. 

Improper installation and handling will cause leakage, electric 

shock or 

fi

 re.

Con

fi

 rm to authorized dealer or specialist on usage of speci

fi

 ed 

refrigerant type. Using of refrigerant other than the speci

fi

 ed 

type may cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive or 

fl

 ammable 

atmosphere. Failure to do so could result in 

fi

 re.

Do not insert your 

fi

 ngers or other objects into the air 

conditioner indoor or outdoor unit, rotating parts may 

cause injury.
Do not touch the outdoor unit during lightning, it may cause 

electric shock.
Do not expose yourself directly to cold air for a long period to 

avoid excess cooling.
Do not sit or step on the unit, you may fall down 

accidentally.

Air Inlet

Air Inlet

Air Outlet

Air Outlet

Air Outlet

Air Outlet

Air Inlet

Air Inlet

Outdoor 

Unit

Indoor 

Unit

Power

Supply

Remote

Control

Summary of Contents for CS-S12NKUW-1

Page 1: ...erating Instructions Air Conditioner Model No Indoor Unit Single Split Outdoor Unit Outdoor Unit CS S9NKUW 1 CU S9NKU 1 CS S12NKUW 1 CU S12NKU 1 CS S18NKU 1 CU S18NKU 1 CS S22NKU 1 CU S22NKU 1 Multi Split Outdoor Unit CU 2S18NBU 1 Panasonic Appliances Air Conditioning Malaysia Sdn Bhd 2012 Unauthorized copying and distribution is a violation of law ...

Page 2: ...an actions that is COMPULSORY WARNING WARNING INDOOR UNIT AND OUTDOOR UNIT This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure...

Page 3: ...he remote control Remove the batteries if the unit is not going to be used for a long period of time New batteries of the same type must be inserted following the polarity stated WARNING WARNING REMOTE CONTROL Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries POWER SUPPLY Do not use a modified cord joint cord extensio...

Page 4: ...ps Multi Split System CS S9NKUW 1 CS S9NKUW 1 CU 2S18NBU 1 25 Amps 208 230V CS S9NKUW 1 CS S12NKUW 1 CU 2S18NBU 1 CS S12NKUW 1 CS S12NKUW 1 CU 2S18NBU 1 Living room Living room Multi Split Outdoor Unit Multi Split Outdoor Unit INDOOR UNIT INDOOR UNIT It is possible to operate the indoor units individually or simultaneously The operation mode priority is given to the first unit that turned on Durin...

Page 5: ...il 1 beep is heard then release Cooling Press the button to turn off 8 AIR PURIFYING FILTER Vacuum the air purifying filter It is recommended to clean the filter every 6 months Replace the filter every 3 years or replace any damaged filter Part no CZ SA20P 9 AIR FILTERS Air filter cleaning is required every two weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dr...

Page 6: ...emperature For Multi Split System COOL mode To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode DRY mode To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation 4 TO SELECT FAN SPEED 5 OPTIONS FAN SPEED For AUTO the indoor fan speed is automatically adjusted according to the operation mode 5 TO ...

Page 7: ...ns NOTES NOTES QUIET POWERFUL Can be activated in all modes and can be cancelled by pressing the respective button again QUIET POWERFUL Cannot be selected at the same time TO SET THE TIMER TO SET THE TIMER To turn ON or OFF the unit at a preset time ON OFF 1 2 SET Select ON or OFF timer Set the time Confirm To cancel ON or OFF timer press ON or OFF then press CANCEL When ON Timer is set the unit m...

Page 8: ...icing Check the following before calling for servicing SYMPTOM SYMPTOM CHECK CHECK Cooling operation is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents Noisy during operation Check if the unit has been installed at an incline Close the front panel properly Remote control does ...

Page 9: ...of this product should follow the manufacturer s refrigerant charging and airflow instructions Failure to confirm proper charge and airflow may reduce energy efficiency and shorten equipment life Federal Communications Commission Interference Statement This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interfe...

Page 10: ...MEMO ...

Page 11: ...MEMO ...

Page 12: ...N SPEED MODE QUIET TEMP OFF ON AIR SWING POWERFUL TIMER SET CANCEL ON OFF 1 2 3 SET CHECK CLOCK RESET AC RC 2 1 3 MODE MODE AUTO DRY COOL Select the desired mode 1 OFF ON OFF ON Start stop the operation 2 TEMP TEMP Select the desired temperature 3 Printed in Malaysia F568314 YS1211 1 Remote Control Preparation Remote Control Preparation 1 2 3 TIMER SET CANCEL ON OFF 1 2 3 SET CHECK CLOCK RESET AC ...

Reviews: