97
2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and
the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the
vane will shift to close position.
* The horizontal vane angle tolerance is /- 5 degree.
14.4.2 Horizontal
Airflow
(RZ25/35TK)
The horizontal airflow direction louver can be adjusted manually by hand.
58°C
50°C
30°C
C
B
A
Indoor Heat
Exchanger Temperature
36°C
Figure 1
Side View (Inner Vane)
Reference point
Stopper
Closed
Position
Step 1
Step 2
Step 3
Step 4
Step 5
110° (RZ25/35TK)
148° (RZ50/60/71/80TK)
Side View (Outer Vane)
Stopper
Closed
Position
Step 1
Step 2
Step 3
Step 4
Step 5
135° (RZ25/35TK)
101° (RZ50/60/71/80TK)
Reference point
Figure 2