![Panasonic CS-RZ25TKR Service Manual Download Page 27](http://html2.mh-extra.com/html/panasonic/cs-rz25tkr/cs-rz25tkr_service-manual_3472471027.webp)
27
Indoor
Model
CS-RZ80TKR
POS (EAN)
5025232871391
Outdoor
Model
CU-RZ80TKR
POS (EAN)
5025232871582
Dimension
Unit
Height (ID / OD)
mm (inch)
302 (11-29/32) / 795 (31-5/16)
Width (ID / OD)
mm (inch)
1102 (43-13/32) / 875 (34-15/32)
Depth (ID / OD)
mm (inch)
244 (9-5/8) / 320 (12-5/8)
PCKG.
(Stacking
Condition)
Height (ID / OD)
mm (inch)
290 (11-7/16) / 894 (35-7/32)
Width (ID / OD)
mm (inch)
1172 (46-5/32) / 1049 (41-5/16)
Depth (ID / OD)
mm (inch)
378 (14-29/32) 485 (19-1/8)
Weight
Net (I/D / O/D)
kg (lb)
13 (29) / 60 (132)
Gross (I/D / O/D)
kg (lb)
15 (33) / 66 (146)
Stacking No. (CS / CU / CZ)
Actual Stacking Quantity (12 / 4 / -)
Piping
Pipe Diameter (Liquid / Gas)
mm (inch
6.35 (1/4) / 15.88 (5/8)
Standard Length
m (ft)
5.0 (16.4)
Length Range ( min - max)
m (ft)
3 (9.8) ~ 30 (98.4)
I/D & O/D Height Different
m (ft)
20 (65.6)
Additional Gas Amount
g/m (oz/ft)
25 (0.3)
Length for Additional (Gas)
m (ft)
10 (32.8)
Drain Hose
Inner Diameter
mm
16.7
Length
mm
650
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row x Stage x FPI
2 x 17 x 17
Size ( W x H x L)
mm
836.5 x 357 x 25.4
Outdoor Heat
Exchanger
Fin Material
Aluminium (Blue Coat)
Fin Type
Corrugated Fin
Row x Stage x FPI
2 x 30 x 19
Size ( W x H x L)
mm
38.1 x 762 x 895.8 : 865.8
Air Filter
Material
Polypropelene
Type
One-Touch
Power Supply
Outdoor Power Supply
Power Supply Cord
NIL
Thermostat
Electronic Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum °C (°F)
32 (89.6)
23 (73.4)
Minimum °C (°F)
16 (60.8)
11 (51.8)
Heating
Maximum °C (°F)
30 (86.0)
-
Minimum °C (°F)
16 (60.8)
-
Outdoor Operation Range
Cooling
Maximum °C (°F)
46 (114.8)
26 (78.8)
Minimum °C (°F)
5 (41.0)
-
Heating
Maximum °C (°F)
24 (75.2)
18 (64.4)
Minimum °C (°F)
-15 (5.0)
-
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3.
Specifications are subjected to change without prior notice for further improvement.