background image

3

English

Quick guide

1

2

3

Inserting the batteries

1

   Pull out the back cover of 

remote control

2

   Insert AAA or R03 batteries 

(can be used ~ 1 year)

3

   Close the cover

CLOCK

SET

CHECK

RESET

AC

RC

ON

OFF

SET

CANCEL

1

2

3

TIMER

SET

CHECK

RESET

AC

RC

ON

OFF

CANCEL

1

3

TIMER

2

3

1

Clock setting

1

   Press CLOCK

2

   Set the time

3

   Confi rm

8m

CLOCK

MODE

AIR CONDITIONER

OFF/ON

SET

CHECK

RESET

AC

RC

ON

OFF

SET

CANCEL

1

2

3

TIMER

MODE

TEMP

FAN SPEED

i AUTO-X

ECONOMY

QUIET

POWERFUL

AIR SWING

AUTO

CLOCK

MODE

AIR CONDITIONER

SET

CHECK

RESET

AC

RC

ON

OFF

SET

CANCEL

1

2

3

TIMER

FAN SPEED

i AUTO-X

ECONOMY

QUIET

POWERFUL

AIR SWING

AUTO

1

3

2

Basic operation

1

  Select the desired mode

AUTO

HEAT

COOL

FAN

i AUTO-X

DRY

2

   Start/stop the operation

POWER

• Please note that the OFF 

indication 

 is on to start. 

3

   Select the desired 

temperature

• Selection range: 16 °C ~ 

30 °C (Not applicable for 
FAN mode).

• Operating the unit within the 

recommended temperature 
may save energy.
HEAT : 20 °C ~ 24 °C. 
COOL: 26 °C ~ 28 °C. 
DRY :  1 °C ~ 2 °C lower than 

room temperature.

• To dim or restore the unit’s 

indicator brightness, press 

 

and hold for 5 seconds.

• Use remote control within 8 m 

from the remote control receiver 
of the indoor unit.

The illustrations in this manual are for explanation purposes 
only and may differ from the actual unit. They are subject to 
change without notice for future improvement.

Table of contents

Safety precautions ...................

4-5

How to use...............................

6-7

To learn more... ..........................

8

Cleaning instructions ..................

9

Troubleshooting  .......................

10

Information................................

11

Accessories

• Remote control
• AAA or R03 batteries × 2
• Remote control holder
• Screws for remote control 

holder × 2

WARNING

This symbol shows 

that this equipment 

uses a 

fl

 ammable 

refrigerant. If the

refrigerant is 

leaked, together 

with an external 

ignition source, 

there is a 

possibility of 

ignition.

CAUTION

This symbol shows 

type of 

fl

 ammable 

refrigerant 

contained in the 

system.

CAUTION

This symbol shows 

that the Operation 

Instructions should 

be read carefully.

CAUTION

This symbol shows 

that a service 

personnel should 

be handling this

equipment with

reference to the

Installation 

Instructions.

CAUTION

This symbol 

shows that there 

is information 

included in 

the Operation 

Instructions and/

or Installation 

Instructions.

F570020-SA0815-1_EN.indd   3

F570020-SA0815-1_EN.indd   3

17/08/2015   2:43:48 PM

17/08/2015   2:43:48 PM

Process Black

Process Black

Summary of Contents for CS-RZ18RKR

Page 1: ...KR Operating Instructions Air Conditioner F570020 Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit read these operating instructions thoroughly and keep them for future reference POWERFUL ECONOMY i AUTO X ...

Page 2: ...ch enable compressor to achieve maximum frequency in a short time i AUTO X also comes with new AEROWINGS twin flaps that works dynamically to adjust airflow directions AEROWINGS gives you fast cooling at start up by directing airflow downwards and comfort of shower cooling by directing airflow upwards So you get to enjoy instant fast cooling satisfaction on a hot day and cooling comfort that goes ...

Page 3: ...than room temperature To dim or restore the unit s indicator brightness press and hold for 5 seconds Use remote control within 8 m from the remote control receiver of the indoor unit The illustrations in this manual are for explanation purposes only and may differ from the actual unit They are subject to change without notice for future improvement Table of contents Safety precautions 4 5 How to u...

Page 4: ...nstallation Instruction table Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock ...

Page 5: ...rvicing When extended non use or During abnormally strong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment...

Page 6: ... the operation mode If i AUTO X mode is set fan speed is fixed to AUTO To adjust fan speed cancel i AUTO X mode POWERFUL ECONOMY i AUTO X Indicator POWER TIMER i AUTO X ECONOMY POWERFUL QUIET Green Orange Orange Orange Orange Orange Remote control receiver i AUTO X To reach temperature quickly Cooling only i AUTO X The unit controls set temperature according to room temperature to accelerate room ...

Page 7: ...again i AUTO X QUIET POWERFUL ECONOMY Cannot be selected at the same time Auto Restart Control If power is resumed after a power failure the operation will restart automatically after a period of time with previous operation mode and airflow direction This control is not applicable when TIMER is set To set the timer 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different ...

Page 8: ...vides efficient comfort cooling to suit your needs DRY Unit operates at low fan speed to give a gentle cooling operation FAN To circulate air in the room i AUTO X The fast cooling is ideal when you come home on a hot day Operation conditions Use this air conditioner under the following temperature range DBT Dry bulb temperature WBT Wet bulb temperature Temperature C Indoor Outdoor DBT WBT DBT WBT ...

Page 9: ...l Indoor unit Aluminium fin Front panel Air filters Anti bacterial filter Air filters Every 2 weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under shade away from fire or direct sunlight Replace any damaged filters Remove air filter Attach air filter Insert into the unit Anti bacterial filter Anti bacterial filter Clean the filter wh...

Page 10: ...te at higher speed to boost cooling performance during initial operation Check the following before calling for servicing Symptom Check Operation in HEAT COOL mode is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents Noisy during operation Check if the unit has been installed at...

Page 11: ...ly valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved Troubleshooting Information ...

Page 12: ...F570020 SA0815 1 Printed in Malaysia Panasonic Corporation Website http www panasonic com Panasonic Corporation 2015 ...

Reviews: