The following symptoms do not indicate malfunction.

Symptom

Cause

Mist emerges from indoor unit.

• Condensation effect due to cooling process.

Water 

fl

 owing sound during operation.

• Refrigerant 

fl

 ow inside the unit.

The room has a peculiar odour.

• This may be due to damp smell emitted by the wall, 

carpet, furniture or clothing.

Indoor fan stops occasionally during automatic 

fan speed setting.

• This helps to remove the surrounding odour.

Air

fl

 ow continues even after operation has 

stopped.

• Extraction of remaining heat from the indoor unit

(maximum 30 seconds).

Operation is delayed a few minutes after 

restarting.

• The delay is a protection to the unit’s compressor.

Outdoor unit emits water/steam.

• Condensation or evaporation occurs on pipes.

TIMER indicator is always on.

• The timer setting repeats daily once set.

POWER indicator blinks during HEAT mode with 

no warm air supply (and 

fl

 ap is closed).

• The unit is in defrost mode (and AIR SWING is set to 

AUTO).

Indoor fan stops occasionally during heating 

operation.

• To avoid unintended cooling effect.

POWER indicator blinks before the unit is 

switched on.

• This is a preliminary step in preparation for the operation 

when the ON timer has been set.

Cracking sound during operation.

• Changes of temperature caused the expansion/contraction 

of the unit.

Discoloration of some plastic parts.

• Discoloration is subject to material types used in plastic 

parts, accelerated when exposed to heat, sun light, UV 

light, or environmental factor.

Louder noise at outdoor unit during early 

operation of i AUTO-X.

• The compressor and fan rotate at higher speed to boost 

cooling performance during initial operation.

Check the following before calling for servicing.

Symptom

Check

Operation in HEAT/COOL mode is not working 

ef

fi

 ciently.

• Set the temperature correctly.

• Close all doors and windows.

• Clean or replace the 

fi

 lters.

• Clear any obstruction at the air inlet and air outlet vents.

Noisy during operation.

• Check if the unit has been installed at an incline.

• Close the front panel properly.

Remote control does not work.

(Display is dim or transmission signal is weak.)

• Insert the batteries correctly.

• Replace weak batteries.

The unit does not work.

• Check if the circuit breaker is tripped.

• Check if timers have been set.

The unit does not receive the signal from the 

remote control.

• Make sure the receiver is not obstructed.

• Certain 

fl

 uorescent lights may interfere with signal 

transmitter. Please consult authorised dealer.

Troubleshooting

NON SERVICEABLE CRITERIAS

TURN OFF POWER SUPPLY AND 

UNPLUG then please consult authorised 

dealer under the following conditions:

• Abnormal noise during operation.

• Water/foreign particles have entered the 

remote control.

• Water leaks from Indoor unit.

• Circuit breaker switches off frequently.

• Power cord becomes unnaturally warm.

• Switches or buttons are not functioning 

properly.

The unit stops and the TIMER indicator blinks.

Use remote control to retrieve error code.

CLOCK

SET

CHECK

RESET

AC

RC

ON

OFF

SET

CANCEL

1

2

3

TIMER

CLOCK

SET

RESET

AC

RC

ON

OFF

SET

CANCEL

1

3

TIMER

Press for 

5 seconds

Press until you 

hear beep sound, 

then write down 

the error code

2

1

Press for 

5 seconds 

to quit 

checking

3

Turn the unit off 

and reveal the 

error code to 

authorised dealer

4

• For certain errors, you may restart the unit for limited 

operation with 4 beeps when operation starts.

F570020-SA0815-1_EN.indd   10

F570020-SA0815-1_EN.indd   10

17/08/2015   2:43:58 PM

17/08/2015   2:43:58 PM

Process Black

Process Black

Summary of Contents for CS-RZ18RKR

Page 1: ...KR Operating Instructions Air Conditioner F570020 Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit read these operating instructions thoroughly and keep them for future reference POWERFUL ECONOMY i AUTO X ...

Page 2: ...ch enable compressor to achieve maximum frequency in a short time i AUTO X also comes with new AEROWINGS twin flaps that works dynamically to adjust airflow directions AEROWINGS gives you fast cooling at start up by directing airflow downwards and comfort of shower cooling by directing airflow upwards So you get to enjoy instant fast cooling satisfaction on a hot day and cooling comfort that goes ...

Page 3: ...than room temperature To dim or restore the unit s indicator brightness press and hold for 5 seconds Use remote control within 8 m from the remote control receiver of the indoor unit The illustrations in this manual are for explanation purposes only and may differ from the actual unit They are subject to change without notice for future improvement Table of contents Safety precautions 4 5 How to u...

Page 4: ...nstallation Instruction table Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock ...

Page 5: ...rvicing When extended non use or During abnormally strong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment...

Page 6: ... the operation mode If i AUTO X mode is set fan speed is fixed to AUTO To adjust fan speed cancel i AUTO X mode POWERFUL ECONOMY i AUTO X Indicator POWER TIMER i AUTO X ECONOMY POWERFUL QUIET Green Orange Orange Orange Orange Orange Remote control receiver i AUTO X To reach temperature quickly Cooling only i AUTO X The unit controls set temperature according to room temperature to accelerate room ...

Page 7: ...again i AUTO X QUIET POWERFUL ECONOMY Cannot be selected at the same time Auto Restart Control If power is resumed after a power failure the operation will restart automatically after a period of time with previous operation mode and airflow direction This control is not applicable when TIMER is set To set the timer 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different ...

Page 8: ...vides efficient comfort cooling to suit your needs DRY Unit operates at low fan speed to give a gentle cooling operation FAN To circulate air in the room i AUTO X The fast cooling is ideal when you come home on a hot day Operation conditions Use this air conditioner under the following temperature range DBT Dry bulb temperature WBT Wet bulb temperature Temperature C Indoor Outdoor DBT WBT DBT WBT ...

Page 9: ...l Indoor unit Aluminium fin Front panel Air filters Anti bacterial filter Air filters Every 2 weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under shade away from fire or direct sunlight Replace any damaged filters Remove air filter Attach air filter Insert into the unit Anti bacterial filter Anti bacterial filter Clean the filter wh...

Page 10: ...te at higher speed to boost cooling performance during initial operation Check the following before calling for servicing Symptom Check Operation in HEAT COOL mode is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents Noisy during operation Check if the unit has been installed at...

Page 11: ...ly valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved Troubleshooting Information ...

Page 12: ...F570020 SA0815 1 Printed in Malaysia Panasonic Corporation Website http www panasonic com Panasonic Corporation 2015 ...

Reviews: