107
1
18. Fan motor can be removed after the
removal of cross flow fan.
17. Remove the cross flow fan from the unit by
pulling it to the left and downward.
Cross flow fan
Evaporator
Reminder: To reinstall the fan motor, adjust
the fan motor connector 45° towards you
before fixing control board.
16. Push the holdfast to the left and liftup the evaporator.
Figure 9
Reminder: To reinstall the cross flow
fan, ensure cross flow fan is in line as
shown in figure 10.
Cross Flow Fan
Figure 10
Summary of Contents for CS-RE9SKUA